Today's Message Index:
----------------------
1. 07:22 AM - alternator switch (klehman@albedo.net)
2. 08:49 AM - Re: Re: OV protection for internally regulated (Jerzy Krasinski)
3. 09:31 AM - Re: Shielded wire options (John Schroeder)
4. 02:21 PM - Wing wiring (Terry Teer)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | alternator switch |
--> AeroElectric-List message posted by: klehman@albedo.net
I still have trouble with the need for absolute alternator control or a
need for an alternator switch. I am referring to an internal vr
alternator. If ov protection trips then I don't want to reset it in
flight unless I suspect a nuisance trip. However nuisance ov tripping is
unacceptable so I would want to correct that or remove the ov
protection. If diodes short then the ANL is going to blow before I can
manually turn off the alternator. If I think that I might have time and
opportunity to turn it off before an impending crash then I'm pretty
sure that I'll already have the engine shutoff and I don't expect my
psru equipped engine to windmill so the alternator will already be dead.
At this point I'm leaning toward a manual battery switch that is not on
the panel so it can't be accidently turned off and no alternator switch.
I'm still thinking about it but such an architecture would also allow me
to run the electrically dependant engine loads through the manual batt
switch. But heh I'm still listening ;) ...
Another option that I'd like is for a reasonable cost replacement for
the heavy (weight and current) contactor that seems to be required to
add ov protection to my 40 amp alternator. With high current silicon
these days, I'd almost think that there would be a way of directly
crowbar shorting/blowing the B lead ANL. Hmmm now that I think about it
there might even be some 100+ amp scr's in my junk box... I think they
came from an AC/DC welder. Fortunately a lighter S704-1 relay seems to
be acceptable for my 20 amp second alternator.
Ken
Yup, Figure Z-24 in the back of the AeroElectric Connection
suggests a means for providing (1) absolute control of an
internally regulated alternator and (2) providing ov
protection.
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: OV protection for internally regulated |
alternators
--> AeroElectric-List message posted by: Jerzy Krasinski <krasinski@direcway.com>
alternators
Jack Bloodgood wrote:
>
>
>Hello,
>
>Just a thought that where appropriate we might profit from the marine
>industry. Almost all private boats have a battery switch which isolates the
>battery and alternator. They have found that alternator diodes blow when
>this switch is opened while the field windings are still energized. The
>alternator is charging into an open circuit.
>
>
From the picture it looks that they are selling $0.70 transorb for $27.99.
Jerzy
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Shielded wire options |
--> AeroElectric-List message posted by: John Schroeder <jschroeder@perigee.net>
You can buy RG400 Coax from Wiremaster for $0.86/ft (Min. of 100 ft order)
vs. $1.50 per ft. for a 100' buy at the source listed below. Wiremasters
also has every gauge of 22759 and in almost every color for prices below
any I have found. Most buys must be 100' min.
They also have milspec M27500-xx TG x T14 (shielded hookup wire). Their 22
AWG 5 conductor is $.94/ ft and their 3 conductor (M27500-22TG3T14) is
$.26 per foot.
Call them at 800 635-5342. Ask for Deb Sullivan. Or email her at
dsullivan@wiremasters.net
Cheers,
John
> In that case I want to pass along this source of the least expensive
> wire that will handle this application. They also stock various
> connectors and antenna wire.
>
> http://www.thewireman.com/index.shtml
>
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
--> AeroElectric-List message posted by: "Terry Teer" <threet@telepak.com>
Just about completed wings on a RV-7 and need some help. Installing landing light,
position light, strobes (in fiberglass tips), nav/com antenna wiring (RG-400),
also a roll servo for the a/p. Should I run all the wires through the 3/4
conduit or should some of them be separated from the rest? Also on the strobe
heads...the whelen strobes say to ground the shielding to the power supply
but in Bob's manual it says to ground the shielding wire to the strobe heads
if mounting in plastic tips. What about it list? This is my second OBAM and
the first to have more advanced equipment and need some advice.
Regards,
Terry
Ackerman, MS
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|