Today's Message Index:
----------------------
1. 03:08 AM - Re: NSI New Chief Engineer (Chuck Jensen)
2. 04:51 AM - Re: Wiring an RV-4 (Robert L. Nuckolls, III)
3. 05:13 AM - Re: recharge/jump start recepticle (Robert L. Nuckolls, III)
4. 07:30 AM - Re: NSI New Chief Engineer (Eric M. Jones)
5. 08:16 AM - Re: Re: Final (REALLY) PMag Update - Part 2 ()
6. 08:36 AM - Re: Re: Final (REALLY) PMag Update - Part 2 (BobsV35B@aol.com)
7. 08:40 AM - Re: recharge/jump start recepticle (John Schroeder)
8. 08:46 AM - AMP connector pin source ()
9. 08:47 AM - Re: Re: Final (REALLY) PMag Update - Part 2 (sportav8r@aol.com)
10. 09:41 AM - Re: AMP connector pin source (rv-9a-online)
11. 10:16 AM - Re: AMP connector pin source (gert)
12. 11:06 AM - Battery In Tail Questions (Sean Stephens)
13. 11:40 AM - Re: recharge/jump start recepticle (courierboy@earthlink.net)
14. 01:39 PM - Re: recharge/jump start recepticle (luckymacy@comcast.net (lucky))
15. 04:55 PM - IR Alternator OVP (speedy11@aol.com)
16. 05:40 PM - Re: IR Alternator OVP (Paul Messinger)
17. 05:40 PM - Re: IR Alternator OVP (Charlie England)
18. 09:23 PM - Re: Antenna Cable Connector Source (rv-9a-online)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | NSI New Chief Engineer |
--> AeroElectric-List message posted by: "Chuck Jensen" <cjensen@dts9000.com>
I'm taken aback.....waaaaaay back. Ah, does this mean Paul will be so
busy in his new job that he won't have time to post to the Connection?
Oh, the Humanity of it.
Chuck
Do Not Archive.
-----Original Message-----
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of Eric
M. Jones
Subject: AeroElectric-List: NSI New Chief Engineer
--> AeroElectric-List message posted by: "Eric M. Jones"
<emjones@charter.net>
Hey AeroElectric Listers,
NSI Aero in Arlington, Washington has been having some organizational
problems recently.
I am pleased to pass on the information that LeGrand Harris, the new
General
Manager, has asked Paul Messinger to be the new chief engineer.
Paul says, "There is a huge task ahead and my first task is to do an
engineering
analysis of the current mechanical and electrical designs and document
concerns and provide engineering updates, as required, both as a quick
fix
and a long term fix as required. Documentation needs to be updated and
operations and limitations need to be written etc."
Let's all wish Paul the very best of luck in this exciting challenge.
Regards,
Eric M. Jones
www.PerihelionDesign.com
113 Brentwood Drive
Southbridge MA 01550-2705
(508) 764-2072
(do not archive)
Don't worry about people stealing an idea. If it's original, you will
have
to ram it down their throats."
-- Howard Aiken
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Wiring an RV-4 |
--> AeroElectric-List message posted by: "Robert L. Nuckolls, III" <nuckollsr@cox.net>
At 04:31 PM 8/20/2005 -0700, you wrote:
>--> AeroElectric-List message posted by: Ron Patterson <scc_ron@yahoo.com>
>
>Hello AeroElectric subscribers,
>
>I'm about to begin the wiring for my RV-4. Considered BMA's printed circut
>board and PTC switch idea, but decided that was too expensive for my 12
>circuits (about $2K).
That's interesting. I didn't know he had actually put
a price on it and was offering it for sale. Of course
we also don't know what all was in the "kit" but $2.000
is a real stretch given what others supply in their
pre-wired, switch panel products for less than half that.
More importantly, the product as last illustrated in
http://www.aeroelectric.com/articles/richter/response_1.pdf
was a long way from being a production offering as it was
plagued with many electrical and mechanical issues.
> Have ordered a Blue Sea 5026 fuse block ($40) and will use Bob's concept
> of fly now, fix on the ground!
>
>I have the following for the panel:
>
>Dynon D10A
>MicroAir T2000 transponder
>XCOM Radio with built-in intercom
>Flightcom i300
>Pictorial Pilot wing leveler
>Altrak altitude hold
>GRT EIS
>Narco 122D VOR/GS with marker beacon
>Garmin 296
>***Considering digital altimeter with encoder vs Dynons encoder or AK 350***
>
>I have cables and pro-hub from Approach Systems for the XCOM, Transponder
>and Narco.
>
>My question is what do I do to wire up the stick-grip push buttons? (PTT,
>Autopilot, starter, electric fuel pump, radio frequency change)... how
>many can go straight to a fuse, vs being regulated before going to the device?
It's not necessary for ANY of the stick-grip wires to
carry supply current. Given the small size of stick grip
switches and wires, it's better to have the stick grip
control the accessory system by GROUNDING. Current
flowing in the stick grip switches should be in
the 100mA to 1A range. Unless the accessory system
can be directly controlled by grounding (like xmit
PTT) then some form of control relays are called for
like the relay decks offered by many for things like
trim servos.
>The Blue Sea has 12 return ground terminals. Should I use these or run a
>seperate ground block?
This will probably not be enough. Have you read the grounding
chapter in the 'Connection Also check out the avionics/panel
grounding concept in chapter 18.
Bob . . .
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: recharge/jump start recepticle |
--> AeroElectric-List message posted by: "Robert L. Nuckolls, III" <nuckollsr@cox.net>
At 07:42 PM 8/20/2005 -0400, you wrote:
>--> AeroElectric-List message posted by: Richard Dudley <rhdudley@att.net>
>
>Hi Chris,
>See Aeroelectric Connection by Bob Nucolls. There is a paper that
>describes an external connection compatible with many FBO's APUs that
>you can build into your RV. That is what I built into my -6A and I use
>it all the time when I want to run the avionics in the hangar. It would
>serve for battery charging, etc. also.
See http://aeroelectric.com/articles/grndpwr.pdf
I'm told that Cole-Hersee now offers the same power jack
with a threaded post so that the modification proposed
in the article is not necessary.
Bob . . .
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: NSI New Chief Engineer |
--> AeroElectric-List message posted by: "Eric M. Jones" <emjones@charter.net>
--> AeroElectric-List message posted by: D Wysong <hdwysong@gmail.com>
>Eric -What happened to Paul's effort with the ghost company (I don't recall
>him ever parting with the name) to develop a "next generation aircraft
>electrical system"... or something along those lines? Did he/they
>shelve the design, scrap it, or is it now in his 'side work' pile?
>Inquiring minds want to know (... well... mine does, anyway).
>Pass along a congrats on the new gig! D
The Ghost Company was NSI. (I would have paid money to see Paul and Lance
Wheeler argue with each other.) The Next Generation electrical system is
not first priority since NSI is in real trouble--"Bigger than you can
imagine trouble."
The Yahoo subie groups (http://groups.yahoo.com/group/E-SubieForum/) have
more information.
Regards,
Eric M. Jones
www.PerihelionDesign.com
113 Brentwood Drive
Southbridge MA 01550-2705
(508) 764-2072
Teamwork: " A lot of people doing exactly what I say."
(Marketing exec., Citrix Corp.)
Message 5
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Final (REALLY) PMag Update - Part 2 |
--> AeroElectric-List message posted by: <chaztuna@adelphia.net>
Stormy,
Your idyllic vision of the gear's life would be true, IF we were dealing with
"constant combustion" (turbine or jet) engines. However, our Lycomings are 4 cylinder
"intermittent combustion" engines. The gears need to be hardened to take
the constant "jack hammering" they receive due to this process. This process
is also what made both Lycoming and Continental quit making geared piston engines.
Charlie Kuss
---- sportav8r@aol.com wrote:
> --> AeroElectric-List message posted by: sportav8r@aol.com
>
> Though I have not spoken yet with anyone knowlegdgeable about this news, your
answer agrees well with my initial impression: the gear is so lightly loaded
in this application (turning an optical encoder wheel in the E-mag and also a
light-duty, rarely-loaded alternator in the P-Mag) that accelerated wear seems
mechanically impossible so long as alignment is correct. If alignment is off,
it's anyone's guess how well the gear would fare, and you'd be glad the soft
gear took the punishment.
>
> -Stormy
>
> -----Original Message-----
> From: Chris & Kellie Hand <ckhand@earthlink.net>
> To: aeroelectric-list@matronics.com
> Subject: Re: AeroElectric-List: Re: Final (REALLY) PMag Update - Part 2
>
>
> --> AeroElectric-List message posted by: "Chris & Kellie Hand"
> <ckhand@earthlink.net>
>
> My RV-6A engine should be ready for me sometime this fall, ordered with an
> e-mag/p-mag combination so this thread definitely caught my attention. I
> asked them about it, and they have the following posted on the Innovation
> section of their web site (http://www.emagair.com/Innovation.htm) :
>
> Q: I read about an occurrence of excessive drive gear wear and your gears
> not being certified. Can you elaborate?
>
> A: As stated on order forms and price lists, our drive gears are not
> certified gears. We try to replicate certified gears in terms of both their
> dimension and their hardness. It was surprising to us (at first) to find
> the certified gear we had tested was not hardened. We then realized there
> would be advantages in keeping the drive gear (accessible and easy to
> replace) unhardened so it will wear before the gear it engages (inside the
> engine and much harder to inspect/replace). Of the numerous in-service
> gears that have come through our shop, we've seen only one (1) occurrence of
> significant wear/deformation of a drive gear. In all likelihood it was
> caused by some kind of foreign matter under one side of the flange when it
> was clamped down. That would have cocked the unit to one side, preload the
> gear, and cause the excessive wear.
>
>
> They also said you do have the option of using a certified gear if desired,
> as I think somebody else pointed out in an earlier reply.
>
> I don't know enough about mag drive gears to know whether certified gears
> are or are not hardened, or whether they should be, but am posting this as
> additional info on the subject and it sounds like emagair has checked on
> that question.
>
> Chris Hand
> RV-6A, finishing kit stage
>
> > >Subject: FW: [c-a] Final (REALLY) PMag Update - Part 2
> > >From: "RV Builder (Michael Sausen)" <rvbuilder@sausen.net>
> > >
> > >Subject: [c-a] Final (REALLY) PMag Update - Part 2
> > >
> > >I would suggest, however, that anyone with an Emag or Pmag on their
> running engine
> > >remove them to examine the gear for wear/damage. Maybe my gear was
> an anomaly
> > >- god knows that I seem to have more than my fair share of them,
> but if there
> > >was a bad run of gears, folks should check to make sure that
> they're not
> > >making metal in their engines, too. Try to file a tip of one gear
> tooth - if
> > >the file takes off metal, it's not hardened. Check with YOUR
> engine experts to
> > >see if they concur that it SHOULD be hardened - that's what Ken and
> his two
> > >guys said.
> > >
> > >Marc J. Zeitlin
> >
> >
> > ---------------------------------
> >
> >
>
>
>
>
>
>
Message 6
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Final (REALLY) PMag Update - Part 2 |
--> AeroElectric-List message posted by: BobsV35B@aol.com
Good Morning Charlie,
I know this is way out of any field of expertise that I may have, but I
wonder if we may not be discussing apples and oranges here?
It would seem to me that those gears in the back of the engine would
encounter much lower stresses than those used to gear down a propellor shaft.
As the
gear only needs to deliver a timing function, I would think that a gear that
had been designed to drive a magneto would have a lot more strength than is
required to drive the timing device needed by the E or P mag unit.
Reduction gearing on the older Lycomings has proven very reliable. So much
so that most engines of that era are overhauled often with nothing being done
to the reduction gears other than careful inspection.
The multi-cylinder radials that powered our piston airline fleets attained
amazingly long gear lives even though they were under very high stresses.
Admittedly, the power pulses came a lot closer together on eighteen cylinder
engines than they do on a four banger, but it does seem that those back of the
engine gears should not have to be terribly sophisticated entities.
Happy Skies,
Old Bob
In a message dated 8/21/2005 10:17:28 AM Central Standard Time,
chaztuna@adelphia.net writes:
Stormy,
Your idyllic vision of the gear's life would be true, IF we were dealing with
"constant combustion" (turbine or jet) engines. However, our Lycomings are 4
cylinder "intermittent combustion" engines. The gears need to be hardened to
take the constant "jack hammering" they receive due to this process. This
process is also what made both Lycoming and Continental quit making geared piston
engines.
Charlie Kuss
Message 7
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: recharge/jump start recepticle |
--> AeroElectric-List message posted by: "John Schroeder" <jschroeder@perigee.net>
Bob -
We installed your ground power system in addition to the Z-14 in our
Lancair ES. I bought a small power supply on eBay that you had recommended
(12V nominal that had been set to 13.5V by the seller). We use it all the
time to check out the electrical system and instrumentation. Great setup.
Works great.
I would like to use the external power receptacle to plug in a battery
charger/maintainer. It should work well to charge/maintain the #1 battery
when just the ground power switch/cb is on and the contactor is closed.
This means we give up .8 amp off the top of the charger's capacity.
However, the problem comes when we want to charge/maintain the #2 battery.
By using the external power jack, we have to have all four of the
contactors closed - giving up 3.2 amps. The entire electrical system of
the aircraft would be hot while the batteries charge. We then worry about
one battery being over charged if the other one is lower. Any
tender/maintainer will stay on the charge cycle until it senses the lowest
battery at the peak charge before going to the maintain mode. Correct?
Question: Is it a good idea to use the ground power system to charge and
maintain the batteries?
If so, can you recommend a maintainer and a circuit change that can do
the job?
Or, would it be better to just add 4 more wires and a couple of plugs to
the batteries and use two of the smaller tenders?
Many thanks,
John Schroeder
Lancair ES 85%
On Sun, 21 Aug 2005 07:06:51 -0500, Robert L. Nuckolls, III
<nuckollsr@cox.net> wrote:
> See http://aeroelectric.com/articles/grndpwr.pdf
> I'm told that Cole-Hersee now offers the same power jack
> with a threaded post so that the modification proposed
> in the article is not necessary.
--
Message 8
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | AMP connector pin source |
--> AeroElectric-List message posted by: <bakerocb@cox.net>
AeroElectric-List message previously posted by: Mickey Coggins
<mick-matronics@rv8.ch>
<<Hi, I'm trying to locate a website where I can buy
AMP pins that go into a strobe AMP connector.
I'm sure someplace like Digikey has them, but
I can't find them on their website.
What I'm looking for is just the pins on
this page:......skip........
Thanks for any hints, or part numbers, or official
unique names! Mickey Coggins>>
8/21/2005
Hello Mickey, I think you may be mixing up Molex and AMP pins and
connectors. Just make sure that you are using the pins and plastic connector
shells from the same manufacturer.
If you are sure that your plastic shells are AMP Mate N Lok brand then you
can get compatible pins from Terminal Town http://www.terminaltown.com/
Pay very close attention to part numbers.
OC
Message 9
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Final (REALLY) PMag Update - Part 2 |
--> AeroElectric-List message posted by: sportav8r@aol.com
Idyllic or not, we'll all have to wait and see what the longer term field experience
is with these gears. For me, the most relevant point is that made by Brad,
who states the Lycoming gears they were copying were also not case-hardened.
If that's correct, we're probably looking at an isolated failure here. Time
will tell.
-Stormy
-----Original Message-----
From: chaztuna@adelphia.net
Subject: Re: AeroElectric-List: Re: Final (REALLY) PMag Update - Part 2
--> AeroElectric-List message posted by: <chaztuna@adelphia.net>
Stormy,
Your idyllic vision of the gear's life would be true, IF we were dealing with
"constant combustion" (turbine or jet) engines. However, our Lycomings are 4
cylinder "intermittent combustion" engines. The gears need to be hardened to
take the constant "jack hammering" they receive due to this process. This
process is also what made both Lycoming and Continental quit making geared
piston engines.
Charlie Kuss
Message 10
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: AMP connector pin source |
--> AeroElectric-List message posted by: rv-9a-online <rv-9a-online@telus.net>
Amp commercial Mate-N-Lock connectors.
Here are the Digi-key part numbers.
A1400-ND CONN RECEPT/CAP 3 POS MATE-N-LOK
A1429-ND CONN PLUG 3POS MATE-N-LOK
A1422-ND CONN PIN 18-24AWG TIN CRIMP
A1423-ND CONN SOCKET 18-24AWG TIN CRIMP
I also used 2-pin and 4-pin versions of these (4-pin is good for strobe
wing root disconnect).
Vern Little RV-9A
bakerocb@cox.net wrote:
>--> AeroElectric-List message posted by: <bakerocb@cox.net>
>
>AeroElectric-List message previously posted by: Mickey Coggins
><mick-matronics@rv8.ch>
>
><<Hi, I'm trying to locate a website where I can buy
>AMP pins that go into a strobe AMP connector.
>
>I'm sure someplace like Digikey has them, but
>I can't find them on their website.
>
>What I'm looking for is just the pins on
>this page:......skip........
>
>Thanks for any hints, or part numbers, or official
>unique names! Mickey Coggins>>
>
>8/21/2005
>
>Hello Mickey, I think you may be mixing up Molex and AMP pins and
>connectors. Just make sure that you are using the pins and plastic connector
>shells from the same manufacturer.
>
>If you are sure that your plastic shells are AMP Mate N Lok brand then you
>can get compatible pins from Terminal Town http://www.terminaltown.com/
>
>Pay very close attention to part numbers.
>
>OC
>
>
>
>
Message 11
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: AMP connector pin source |
--> AeroElectric-List message posted by: gert <gert.v@sbcglobal.net>
there is a difference between regular Mate-N-Lock and *Commercial*
Mate-N-Lock.
the strobes had the Commercial variety of Mate-n-Lock connectors, once I
figured that out getting additional items was easy.
I believe SteinAir sells the regular Mate-N-Lock, I know, I bought some
of his 2, for a different purpose.
bakerocb@cox.net wrote:
>--> AeroElectric-List message posted by: <bakerocb@cox.net>
>
>AeroElectric-List message previously posted by: Mickey Coggins
><mick-matronics@rv8.ch>
>
><<Hi, I'm trying to locate a website where I can buy
>AMP pins that go into a strobe AMP connector.
>
>I'm sure someplace like Digikey has them, but
>I can't find them on their website.
>
>What I'm looking for is just the pins on
>this page:......skip........
>
>Thanks for any hints, or part numbers, or official
>unique names! Mickey Coggins>>
>
>8/21/2005
>
>Hello Mickey, I think you may be mixing up Molex and AMP pins and
>connectors. Just make sure that you are using the pins and plastic connector
>shells from the same manufacturer.
>
>If you are sure that your plastic shells are AMP Mate N Lok brand then you
>can get compatible pins from Terminal Town http://www.terminaltown.com/
>
>Pay very close attention to part numbers.
>
>OC
>
>
>
>
--
is subject to a download and archival fee in the amount of $500
Message 12
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Battery In Tail Questions |
--> AeroElectric-List message posted by: Sean Stephens <schmoboy@cox.net>
First off, I'd like to make the statement that I am a "noob" when it
comes to some of these things, but I am slowly putting things together
after reading The Connection and lurking here. So be gentle if I use
some incorrect "terminology". :)
I will most likely have some form of Z-13. At this point most likely a
Z-13/Z-30 derivative. The dual bats will be in the tail.
I believe that a good place to establish the main power distribution bus
connection is to connect from the starter contactor. Maybe an ANL
between? Is that correct?
My biggest sticking point is with the bat bus and aux bat bus being in
the tail. The feeds to the bat/aux bat bus items along with the e-bus
alt feed will have to run the length of the fuse. I read in The
Connection that it is wise to run all these wires along one side of the
plane (Page-7 Note 5)? Is it ok to have all the large and small wires
routed together in one conduit? Are there other issues I have to be
concerned with?
Maybe I'm just making too big a deal out of it and as long as my fuses
and wires are properly sized, the battery buses being located in the
tail will be just fine? I guess I just need confirmation that I'm on
the right track and maybe a few "gotchas" that I need to look out for.
Thanks All...
-Sean RV-10 #40303
http://rv10.stephensville.com
Message 13
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: recharge/jump start recepticle |
--> AeroElectric-List message posted by: courierboy@earthlink.net
>--> AeroElectric-List message posted by: "chris macy" <luckymacy@comcast.net>
>
>Hi,
>I'm looking for a way to be able to recharge or jumpstart my battery
>from outside the plane which is in the back of an RV8.
>
>What I have in mind is a receptacle which is flush with the bottom
>of the fuse and has a rubber plug to seal it while not in use. I
>want the wire sized to be able to handle the current of a jump start
>and bolted to the battery just like the start/ground cables are. I
>am not aware I've seen something like this before except for a
>bigger version like an APU jack in military aircraft but that's
>overkill for an RV. But I thought I heard it discussed in past
>years on the list but my archive search didn't turn up anything. I
>was hoping West Marine would have something similar but I didn't
>find anything.
>
>Any ideas?
>
>thx,
>lucky
lucky -
This is not exactly what you describe but worth looking at:
http://solanopilots.com/quickjumpsolution.htm
Find more ideas at the AEC web site at "How to Articles" under
"Downloadable Reference Materials". Click on "Low Cost Ground Power
Jack for Your Airplane"
Bill
Message 14
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: recharge/jump start recepticle |
--> AeroElectric-List message posted by: luckymacy@comcast.net (lucky)
Thanks for all the responses. I ordered the Piper receptical and plug from ACS.
It's just what I was looking for and the link below confirmed it. I think
it can easily work for both a battery tender and jump starter.
Lucky
-------------- Original message --------------
> --> AeroElectric-List message posted by: courierboy@earthlink.net
>
> >--> AeroElectric-List message posted by: "chris macy"
> >
> >Hi,
> >I'm looking for a way to be able to recharge or jumpstart my battery
> >from outside the plane which is in the back of an RV8.
> >
> >What I have in mind is a receptacle which is flush with the bottom
> >of the fuse and has a rubber plug to seal it while not in use. I
> >want the wire sized to be able to handle the current of a jump start
> >and bolted to the battery just like the start/ground cables are. I
> >am not aware I've seen something like this before except for a
> >bigger version like an APU jack in military aircraft but that's
> >overkill for an RV. But I thought I heard it discussed in past
> >years on the list but my archive search didn't turn up anything. I
> >was hoping West Marine would have something similar but I didn't
> >find anything.
> >
> >Any ideas?
> >
> >thx,
> >lucky
>
>
> lucky -
>
> This is not exactly what you describe but worth looking at:
> http://solanopilots.com/quickjumpsolution.htm
>
> Find more ideas at the AEC web site at "How to Articles" under
> "Downloadable Reference Materials". Click on "Low Cost Ground Power
> Jack for Your Airplane"
>
> Bill
>
>
>
>
>
>
Thanks for all the responses. I ordered the Piper receptical and plug from ACS.
It's just what I waslooking for and the link below confirmed it. I think it can
easily work for both a battery tender and jump starter.
Lucky
-------------- Original message --------------
-- AeroElectric-List message posted by: courierboy@earthlink.net
-- AeroElectric-List message posted by: "chris macy" <LUCKYMACY@COMCAST.NET>
Hi,
I'm looking for a way to be able to recharge or jumpstart my battery
from outside the plane which is in the back of an RV8.
What I have in mind is a receptacle which is flush with the bottom
of the fuse and has a rubber plug to seal it while not in use. I
want the wire sized to be able to handle the current of a jump start
and bolted to the battery just like the start/ground cables are. I
am not aware I've seen something like this before except for a
bigger version like an APU jack in military aircraft but that's <BR
> overkill for an RV. But I thought I heard it discussed in past
years on the list but my archive search didn't turn up anything. I
was hoping West Marine would have something similar but I didn't
find anything.
Any ideas?
thx,
lucky
lucky -
This is not exactly what you describe but worth looking at:
http://solanopilots.com/quickjumpsolution.htm
Find more ideas at the AEC web site at "How to Articles" under
"Downloadable Reference Materials". Click on "Low Cost Ground Power
Jack for Your Airplane"
Bill
criptions page,
Message 15
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | IR Alternator OVP |
--> AeroElectric-List message posted by: speedy11@aol.com
Suppose one installed an internally regulated alternator and wanted overvoltage
protection.
Suppose the alternator has a B lead to power the bus, a S lead to sense voltage
on the bus and adjust the alternator output, and a "G" lead for grounding.
Question 1 - would breaking the ground wire cause the alternator to quit?
Question 2 - If so, then could one have a sensor on the B lead that, during an
overvoltage, would command a contactor in the ground wire to open and thus shut
down the alternator?
Question 3 - Could said contactor be a solid state relay instead?
Ready for the flames.
Stan Sutterfield
RV-8A
Message 16
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: IR Alternator OVP |
--> AeroElectric-List message posted by: "Paul Messinger" <paulm@olypen.com>
The common alternators are not wired that way.
There is a I lead that is alternator control when it is working properly and
opening and closing the I lead turns on and off the output power coming from
the "B" terminal.
The L terminal is part of the so called IDIOT light in autos and really only
a ground lead for a light.
Some also have a S lead for remote voltage sensing so voltage drop from the
B lead to the battery can be allowed for.
The ground is the alternator case and not something to be controlled.
The problem with internally regulated alternators is IF (extremely rare) the
internal power transistor in the internal field lead shorts there is no way
to remove field power and the B lead will become a constant current source
and the 55 amp alternator will try to provide 70 or more amps. The B lead
voltage will quickly rise until the system bus absorbs 70 amps. The battery
(once fully charged) will not clamp the voltage and in many cases the
voltage rises from 14v to over 24 volts at around 1/2 volt per second and
can end up over 30 volts if that is what is needed to load the alternator.
Its true the 70 amps will decrease as the voltage rises but in the interim
your electrical system is subject to massive failure from overvoltage if
nothing is done.
The OVP designs floating around including aeroelectric list have
demonstrated on Vans aircraft to apparently create alternator failures. The
problem may be the contactor used and the common contactor is not designed
for and will NOT work reliably in this application. Only a contactor
designed for this application will work and one device is the Kilovac unit
that is rated for the very high arcing voltages present.
The redesigned NSI system will have a reliable OV protection option.
Lots more later but you are much more likely to have an engine failure than
an alternator High voltage output failure. Current solid state technology is
not cost effective (for the B lead circuit) but costs are dropping.
Paul
PS I have thrown my flamethrower in the trash given my new position at NSI.
There are no dumb questions just dumb replys. An educated pilot is a safer
pilot.
----- Original Message -----
From: <speedy11@aol.com>
Subject: AeroElectric-List: IR Alternator OVP
> --> AeroElectric-List message posted by: speedy11@aol.com
>
>
> Suppose one installed an internally regulated alternator and wanted
> overvoltage protection.
> Suppose the alternator has a B lead to power the bus, a S lead to sense
> voltage on the bus and adjust the alternator output, and a "G" lead for
> grounding.
> Question 1 - would breaking the ground wire cause the alternator to quit?
> Question 2 - If so, then could one have a sensor on the B lead that,
> during an overvoltage, would command a contactor in the ground wire to
> open and thus shut down the alternator?
> Question 3 - Could said contactor be a solid state relay instead?
> Ready for the flames.
> Stan Sutterfield
> RV-8A
>
>
>
Message 17
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: IR Alternator OVP |
--> AeroElectric-List message posted by: Charlie England <ceengland@bellsouth.net>
speedy11@aol.com wrote:
>--> AeroElectric-List message posted by: speedy11@aol.com
>
>
> Suppose one installed an internally regulated alternator and wanted overvoltage
protection.
>Suppose the alternator has a B lead to power the bus, a S lead to sense voltage
on the bus and adjust the alternator output, and a "G" lead for grounding.
>Question 1 - would breaking the ground wire cause the alternator to quit?
>Question 2 - If so, then could one have a sensor on the B lead that, during an
overvoltage, would command a contactor in the ground wire to open and thus shut
down the alternator?
>Question 3 - Could said contactor be a solid state relay instead?
>Ready for the flames.
>Stan Sutterfield
>RV-8A
>
It's likely that the case is common with the G terminal. You can check
with an ohm meter. Even if it isn't, there would be no advantage to
breaking the ground because the same current flows in the return path as
the B+ path. As long as the solid state relay can handle the voltage &
current, sure, it will work.
(There are all kinds of subtle reasons why you can and/or can't do any
of the above, but the experts would have to kill you if they explained
it.) < obligatory :-) >
Charlie
Message 18
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Antenna Cable Connector Source |
--> AeroElectric-List message posted by: rv-9a-online <rv-9a-online@telus.net>
Check with an avionics shop... this is only available from Garmin. It's
a horrendous price, about $20.00. My avionics shop said to use the
solder tail connector, then put an in-line BNC connector in the coax,
which is what I did.
Vern Little
DAVID REEL wrote:
>--> AeroElectric-List message posted by: "DAVID REEL" <dreel@cox.net>
>
>No luck in the archives. Does anyone have a source for the BNC type coaxial cable
connector attached to the transponder tray with a snap ring on the Garmin
GTX320A? My unit came with a solder type connector & I would like to have a
BNC style connection to simplify panel removal. The Garmin part number is 330-00326-00.
>
>Dave Reel - RV8A
>
>
>
>
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|