1. 12:15 AM - 2009 List of Contributors (Matt Dralle)
2. 04:16 AM - Re: 120 volt connectors (bob noffs)
3. 04:31 AM - In-line Battery Fuse; great find (Jay Hyde)
4. 07:42 AM - Re: In-line Battery Fuse; great find ()
5. 07:53 AM - GFCI and PRE-HEATERS (racerjerry)
6. 08:17 AM - Re: GFCI and PRE-HEATERS (Richard Girard)
7. 08:23 AM - Re: 120 volt connectors (Robert L. Nuckolls, III)
8. 08:24 AM - Re: In-line Battery Fuse; great find (Robert L. Nuckolls, III)
9. 08:56 AM - Re: GFCI and PRE-HEATERS (racerjerry)
10. 09:24 AM - Re: Re: GFCI and PRE-HEATERS ()
11. 09:45 AM - Re: In-line Battery Fuse; great find (Jay Hyde)
12. 09:45 AM - Re: In-line Battery Fuse; great find (Jay Hyde)
13. 10:25 AM - Re: Re: GFCI and PRE-HEATERS (bob noffs)
14. 11:49 AM - Re: In-line Battery Fuse; great find (Robert L. Nuckolls, III)
15. 03:24 PM - duracell battery leak (ray)
16. 03:54 PM - Re: duracell battery leak (ray)
17. 04:35 PM - Re: Duracell battery leak (S. Ramirez)
18. 04:52 PM - Re: Re: GFCI and PRE-HEATERS (Ed Anderson)
19. 07:34 PM - Re: Re: Power Opti-Miser (Robert L. Nuckolls, III)
20. 11:25 PM - Re: Ammeter help (Keith Burris)
21. 11:38 PM - Re: In-line Battery Fuse; great find (Jay Hyde)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | 2009 List of Contributors |
Dear Listers,
The 2009 Matronics Email List and Forum Fund Raiser officially ended a couple of
weeks ago and its time that I publish this year's List of Contributors. Its
the people on this list that directly make the Email Lists and Forums possible.
Their generous
contributions keep the servers and Internet connection up and running.
You can still show your support this year and pick up a great gift at the same
time. The Contribution Web Site is fast, easy, and secure:
http://www.matronics.com/contribution
I also want to thank Bob, Jon, Andy, and John for their generous support through
the supply of great gifts this year!! These guys have some great products and
I encourage you to visit their respective web sites:
Bob Nucklolls - AeroElectric - www.aeroelectric.com
Jon Croke - HomebuiltHELP - www.homebuilthelp.com
Andy Gold - The Builder's Bookstore - www.buildersbooks.com
John Caldwell - HowToCrimp - www.howtocrimp.com
And finally, I'm proud to present The 2009 Fund Raiser List of Contributors:
http://www.matronics.com/loc/2009.html
Thanks again to everyone that made a Contribution this year!!
Matt Dralle
Matronics Email List and Forum Administrator
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: 120 volt connectors |
hi all,
thanks for all the ideas. i think i will go with the computer receptacle
and knife splices. i would only need the knife splices if a heat pad fails
and i can carry the computer cord in the airplane.
bob noffs
On Sun, Dec 20, 2009 at 9:02 PM, Robert L. Nuckolls, III <
nuckolls.bob@aeroelectric.com> wrote:
> nuckolls.bob@aeroelectric.com>
>
>
> At 03:41 PM 12/20/2009, you wrote:
>
>> i guess my question wasn.t clear. i am concerned about what type of radio
>> shack connector will be acceptable for 120 volts where each heatpad lead
>> connects to the ''main'' lead. i would see the ''main lead'' wired into the
>> ac chassis socket.
>>
>
> "Acceptable" is a hard term to define. The concerns
> for any wiring that carries a lot of voltage and
> supplied from an energetic source (15A or better
> breaker) is integrity of the connections. When
> folks wire such devices in houses, they're either
> spliced permanently and independently insulated
> or semi-permanent connection (wire nut, screw clamp,
> etc) inside a suitable enclosure.
>
> The knife splices are as close as you can get to
> permanent and still open the joints for maintenance.
> Soldered splices under heat shrink would be the
> most "acceptable" in terms of mechanical robustness.
>
> If you're prepared to live with anything less, then
> about any connector in the catalog will do.
>
> Bob . . .
>
> \
>>
>
>
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | In-line Battery Fuse; great find |
I came across a great inline battery fuse that simplified my life a lot- see
the picture.
I found it at our local RS Components store (part number 337-7921 for the
75A version). Search www.rssouthafrica.com <http://www.rssouthafrica.com/>
using the part number to see more. I'm sure that you will be able to find
similar things elsewhere.
Jay
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | In-line Battery Fuse; great find |
Jay,
Nice looking product. Many auto manufacturers use a similar approach
with a cheaper fuse link or glass fuse (old jobs). Do they have one for
a 10mm bolt?
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of Jay
Hyde
Sent: Monday, December 21, 2009 7:26 AM
Subject: AeroElectric-List: In-line Battery Fuse; great find
I came across a great inline battery fuse that simplified my life a lot-
see the picture.
I found it at our local RS Components store (part number 337-7921 for
the 75A version). Search www.rssouthafrica.com
<http://www.rssouthafrica.com/> using the part number to see more. I'm
sure that you will be able to find similar things elsewhere.
Jay
Message 5
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | GFCI and PRE-HEATERS |
With the cold weather, I see great interest in homemade 120 VAC powered pre-heat
systems for our aircraft. A truly wonderful and very inexpensive device was
developed quite some time ago that can easily save you life; the Ground Fault
Circuit Interrupter. Fuses and circuit breakers do absolutely NOTHING to protect
you; they are sized to protect wiring and equipment. One tenth of one amp
(0.1 amp) can quite easily kill a healthy adult (I am not kidding). If you
are planning to drag extension cords through the snow, you definitely need GFCI
protection.
Since they sense differential current, GFCIs offer protection even when operating
off of old style 2-wire (ungrounded) circuits. You can buy a plug-in GFCI
for use at the airport or even better, make your own extension cord by mounting
a normal GFCI into a steel electrical box along with a heavy 3-wire appliance
cord and use it for ALL your power tools. This setup wont protect if you are
dumb enough to put your fingers across hot and neutral, but works extremely
well if you touch something electrically hot and your body happens to be even
slightly grounded (through dampness or touching grounded metal) or are using that
old metal housing portable electric drill you found in the trash with frayed
insulation and with the grounding prong clipped off.
Seriously, always power your 120 VAC tools through a Ground Fault Circuit Interrupter
protected circuit. Also, before you use that homemade pre-heat setup in
the snow, please remember these four letters: GFCI. We are having too much
fun. It could save your life.
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=278441#278441
Message 6
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: GFCI and PRE-HEATERS |
Since a GCFI protects everything downstream of it, why would you not simply
install one in place of the hangar receptacle and use a regular extension
cord?
Rick Girard
On Mon, Dec 21, 2009 at 9:47 AM, racerjerry <gki@suffolk.lib.ny.us> wrote:
> gki@suffolk.lib.ny.us>
>
> With the cold weather, I see great interest in homemade 120 VAC powered
> pre-heat systems for our aircraft. A truly wonderful and very inexpensiv
e
> device was developed quite some time ago that can easily save you life; t
he
> Ground Fault Circuit Interrupter. Fuses and circuit breakers do absolute
ly
> NOTHING to protect you; they are sized to protect wiring and equipment.
One
> tenth of one amp (0.1 amp) can quite easily kill a healthy adult (I am no
t
> kidding). If you are planning to drag extension cords through the snow,
you
> definitely need GFCI protection.
>
> Since they sense differential current, GFCI=92s offer protection even whe
n
> operating off of old style 2-wire (ungrounded) circuits. You can buy a
> plug-in GFCI for use at the airport or even better, make your own extensi
on
> cord by mounting a normal GFCI into a steel electrical box along with a
> heavy 3-wire appliance cord and use it for ALL your power tools. This se
tup
> won=92t protect if you are dumb enough to put your fingers across hot and
> neutral, but works extremely well if you touch something electrically hot
> and your body happens to be even slightly grounded (through dampness or
> touching grounded metal) or are using that old metal housing portable
> electric drill you found in the trash with frayed insulation and with the
> grounding prong clipped off.
>
> Seriously, always power your 120 VAC tools through a Ground Fault Circuit
> Interrupter protected circuit. Also, before you use that homemade pre-he
at
> setup in the snow, please remember these four letters: GFCI. We are havi
ng
> too much fun. It could save your life.
>
>
> Read this topic online here:
>
> http://forums.matronics.com/viewtopic.php?p=278441#278441
>
>
===========
===========
===========
===========
>
>
Message 7
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: 120 volt connectors |
At 06:13 AM 12/21/2009, you wrote:
>hi all,
> thanks for all the ideas. i think i will go with the computer
> receptacle and knife splices. i would only need the knife splices
> if a heat pad fails and i can carry the computer cord in the airplane.
If you can, see what the Tannis folks do about wiring
up heaters on TC aircraft. Have the "computer"
cord receptacle face downward in the airplane.
Bob . . .
Message 8
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: In-line Battery Fuse; great find |
At 06:25 AM 12/21/2009, you wrote:
>I came across a great inline battery fuse that simplified my life a
>lot- see the picture.
>
>I found it at our local RS Components store (part number 337-7921
>for the 75A version). Search
><http://www.rssouthafrica.com/>www.rssouthafrica.com using the part
>number to see more. I'm sure that you will be able to find similar
>things elsewhere.
In what applications have you found this
product to be useful?
Bob . . .
Message 9
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: GFCI and PRE-HEATERS |
Quote: "Since a GCFI protects everything downstream of it, why would you not simply
install one in place of the hangar receptacle and use a regular extension
cord?
Rick Girard "
I strongly agree; replacement of the wall outlet with a standard GFCI is ABSOLUTELY
THE PREFERRED METHOD! BUT, if you have to use someone else's facility, or
are temporarily operating off of a power pole, a portable GFCI setup is a viable
alternative. Also, use an inexpensive plug-in polarity checker to check
for reversed wiring.
Jerry King
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=278451#278451
Message 10
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: GFCI and PRE-HEATERS |
Just a thought, but you may not own the hangar or have rights to change
stuff? You may be parked outside and dragging a 50ft extension from the
nearest plug while standing in melting snow?
-----Original Message-----
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of
racerjerry
Sent: Monday, December 21, 2009 11:52 AM
Subject: AeroElectric-List: Re: GFCI and PRE-HEATERS
<gki@suffolk.lib.ny.us>
Quote: "Since a GCFI protects everything downstream of it, why would you
not simply install one in place of the hangar receptacle and use a
regular extension cord?
Rick Girard "
I strongly agree; replacement of the wall outlet with a standard GFCI is
ABSOLUTELY THE PREFERRED METHOD! BUT, if you have to use someone else's
facility, or are temporarily operating off of a power pole, a portable
GFCI setup is a viable alternative. Also, use an inexpensive plug-in
polarity checker to check for reversed wiring.
Jerry King
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=278451#278451
Message 11
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | In-line Battery Fuse; great find |
Doesn't look like it- but perhaps you can make an extension from your
battery post to go down to an 8mm hole as I described in my other mail.
Jay
_____
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of
longg@pjm.com
Sent: 21 December 2009 05:37 PM
Subject: RE: AeroElectric-List: In-line Battery Fuse; great find
Jay,
Nice looking product. Many auto manufacturers use a similar approach with a
cheaper fuse link or glass fuse (old jobs). Do they have one for a 10mm
bolt?
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of Jay Hyde
Sent: Monday, December 21, 2009 7:26 AM
Subject: AeroElectric-List: In-line Battery Fuse; great find
I came across a great inline battery fuse that simplified my life a lot- see
the picture.
I found it at our local RS Components store (part number 337-7921 for the
75A version). Search www.rssouthafrica.com <http://www.rssouthafrica.com/>
using the part number to see more. I'm sure that you will be able to find
similar things elsewhere.
Jay
Message 12
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | In-line Battery Fuse; great find |
I used it to protect a long fat wire from my aux/ 2nd battery which is
located at the back of the aircraft. I had quite a small space to work
in
and hadn't thought about protecting the wire in the first place, but
realized that I needed to put some form of protection in. Whilst
searching
for a local ANL type device I came across this and realized that I
wouldn't
need to add the ANL base; since there wasn't much space to work in that
was
a great relief.
The picture that I added isn't completely clear- the device itself is
just
the white/cream coloured box with a clear top that is between the lug
and
the battery terminal. My battery terminals are flat but the holes in
them
are too small for an 8mm bolt so I added a copper extension with an 8mm
hole
to bolt the fuse to. I also had to make an insulating washer to
insulate
the nut as I had not ordered the insulating nut that is shown in the
picture.
Jay
_____
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of
Robert L.
Nuckolls, III
Sent: 21 December 2009 06:21 PM
Subject: Re: AeroElectric-List: In-line Battery Fuse; great find
At 06:25 AM 12/21/2009, you wrote:
I came across a great inline battery fuse that simplified my life a lot-
see
the picture.
I found it at our local RS Components store (part number 337-7921 for
the
75A version). Search www.rssouthafrica.com
<http://www.rssouthafrica.com/>
using the part number to see more. I=12m sure that you will be able to
find
similar things elsewhere.
In what applications have you found this
product to be useful?
Bob . . .
Message 13
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: GFCI and PRE-HEATERS |
i agree with the importance of a gfi. my experience with the gfi
weatherproof receptacle for plugging my car block heaters in [20 below f is
common here] was that they were always tripping. i removed them and put in
gfi circuit breakers in my circuit breaker panel. reliability went way up.
yes, they are installed correctly in my panel.
bob noffs
On Mon, Dec 21, 2009 at 11:16 AM, <longg@pjm.com> wrote:
>
> Just a thought, but you may not own the hangar or have rights to change
> stuff? You may be parked outside and dragging a 50ft extension from the
> nearest plug while standing in melting snow?
>
> -----Original Message-----
> From: owner-aeroelectric-list-server@matronics.com
> [mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of
> racerjerry
> Sent: Monday, December 21, 2009 11:52 AM
> To: aeroelectric-list@matronics.com
> Subject: AeroElectric-List: Re: GFCI and PRE-HEATERS
>
> <gki@suffolk.lib.ny.us>
>
> Quote: "Since a GCFI protects everything downstream of it, why would you
> not simply install one in place of the hangar receptacle and use a
> regular extension cord?
>
> Rick Girard "
>
> I strongly agree; replacement of the wall outlet with a standard GFCI is
> ABSOLUTELY THE PREFERRED METHOD! BUT, if you have to use someone else's
> facility, or are temporarily operating off of a power pole, a portable
> GFCI setup is a viable alternative. Also, use an inexpensive plug-in
> polarity checker to check for reversed wiring.
>
> Jerry King
>
>
> Read this topic online here:
>
> http://forums.matronics.com/viewtopic.php?p=278451#278451
>
>
Message 14
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | In-line Battery Fuse; great find |
At 11:35 AM 12/21/2009, you wrote:
>I used it to protect a long fat wire from my aux/ 2nd battery which
>is located at the back of the aircraft. I had quite a small space
>to work in and hadn't thought about protecting the wire in the first
>place, but realized that I needed to put some form of protection
>in. Whilst searching for a local ANL type device I came across this
>and realized that I wouldn't need to add the ANL base; since there
>wasn't much space to work in that was a great relief.
Hmmmm . . . conventional wisdom in TC aircraft calls
for no single always-hot wire to be protected at more
than 5A (breakered) from which I extrapolated 7A (fused).
FAT feeders from a battery normally call for at least
a mini-contactor like . . .
http://www.aeroelectric.com/PPS/Adobe_Architecture_Pdfs/Z32K.pdf
"If the bus isn't at the battery, it's not a battery bus"
Bob . . .
Message 15
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | duracell battery leak |
Listers,
Just another data point. I had a Duracell AA battery sitting in a
battery holder on a shelf and I just looked at and the bottom had leaked
while it was sitting in the holder. This has been stored at room temp
and was slightly used but showed good on the little built in tester when
I put it in the holder.
Raymond Julian
Message 16
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: duracell battery leak |
I found the battery. It was a AAA with an expiration of Mar 2010. It
still showed over 1.3 volts once I cleaned the crud off.
Raymond Julian
Kettle River, MN
do not archive
ray wrote:
>
> Listers,
>
> Just another data point. I had a Duracell AA battery sitting in a
> battery holder on a shelf and I just looked at and the bottom had leaked
> while it was sitting in the holder. This has been stored at room temp
> and was slightly used but showed good on the little built in tester when
> I put it in the holder.
>
> Raymond Julian
>
>
>
>
>
>
>
Message 17
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Duracell battery leak |
Ray,
I've heard too many sob stories about Duracell alkalines. I've also heard a
few sob stories about Ray-O-Vacs. I decided that alkalines aren't worth
having in my toys, so I've gone with lithium AA and AAA batteries by
ordering them from www.batteryjunction.com to offset some of the cost. I
don't have any data that says lithium is any better, but my reasoning is
that manufacturers control leakage better from lithium batteries because
they are more dangerous. Does anyone have data on leakage from lithium AA
and AAA batteries?
Simon Ramirez
Copyright 2009
-----Original Message-----
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of ray
Sent: Monday, December 21, 2009 6:53 PM
Subject: Re: AeroElectric-List: duracell battery leak
I found the battery. It was a AAA with an expiration of Mar 2010. It
still showed over 1.3 volts once I cleaned the crud off.
Raymond Julian
Kettle River, MN
do not archive
ray wrote:
>
> Listers,
>
> Just another data point. I had a Duracell AA battery sitting in a
> battery holder on a shelf and I just looked at and the bottom had leaked
> while it was sitting in the holder. This has been stored at room temp
> and was slightly used but showed good on the little built in tester when
> I put it in the holder.
>
> Raymond Julian
>
>
>
>
>
>
>
Message 18
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: GFCI and PRE-HEATERS |
I wired my hangar a couple of years ago, running the wire through conduct.
I decided to use a common neutral wire between the two 120 volt phases to
reduce the size of the wire to be run through the conduct and to have two
separate circuits.
Well, the wiring worked fine. However, I decided to install GFCI circuit
breakers in the electric box to provide some protection. To make a long
story short, I discovered that some GFCI circuit breakers will not work
wired to a common neutral. I was attempting to use one plug on the socket
to carry one 120 volt circuit and the other plug to carry the other 120 volt
circuit and the common neutral. Just did not work and I finally found in
very fine print on the carton that this particular GFCI simply would not
work with my set up.
Ed
Ed Anderson
Rv-6A N494BW Rotary Powered
Matthews, NC
eanderson@carolina.rr.com
<http://www.andersonee.com> http://www.andersonee.com
<http://www.dmack.net/mazda/index.html>
http://www.dmack.net/mazda/index.html
http://www.flyrotary.com/
<http://members.cox.net/rogersda/rotary/configs.htm>
http://members.cox.net/rogersda/rotary/configs.htm#N494BW
http://www.rotaryaviation.com/Rotorhead%20Truth.htm
<http://www.dmack.net/mazda/index.html>
_____
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of bob noffs
Sent: Monday, December 21, 2009 1:23 PM
Subject: Re: AeroElectric-List: Re: GFCI and PRE-HEATERS
i agree with the importance of a gfi. my experience with the gfi
weatherproof receptacle for plugging my car block heaters in [20 below f is
common here] was that they were always tripping. i removed them and put in
gfi circuit breakers in my circuit breaker panel. reliability went way up.
yes, they are installed correctly in my panel.
bob noffs
On Mon, Dec 21, 2009 at 11:16 AM, <longg@pjm.com> wrote:
Just a thought, but you may not own the hangar or have rights to change
stuff? You may be parked outside and dragging a 50ft extension from the
nearest plug while standing in melting snow?
-----Original Message-----
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of
racerjerry
Sent: Monday, December 21, 2009 11:52 AM
Subject: AeroElectric-List: Re: GFCI and PRE-HEATERS
<gki@suffolk.lib.ny.us>
Quote: "Since a GCFI protects everything downstream of it, why would you
not simply install one in place of the hangar receptacle and use a
regular extension cord?
Rick Girard "
I strongly agree; replacement of the wall outlet with a standard GFCI is
ABSOLUTELY THE PREFERRED METHOD! BUT, if you have to use someone else's
facility, or are temporarily operating off of a power pole, a portable
GFCI setup is a viable alternative. Also, use an inexpensive plug-in
polarity checker to check for reversed wiring.
Jerry King
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=278451#278451
-= * AeroElectric www.aeroelectric.com <http://www.aeroelectric.com/>
omebuiltHELP www.homebuilthelp.com <http://www.homebuilthelp.com/>
contribution" target="_blank">http://www.matronics.com/contribution
-Matt Dralle, Li - The AeroElectric-List
Email Forum -
:
oElectric-List"
target="_blank">http://www.matronics.com/Navigator?AeroEl==================
http://forums.m=========== <http://forums.matronics.com/>
<http://forums.matronics.com/>
<http://forums.matronics.com/>
<http://forums.matronics.com/>
<http://forums.matronics.com/>
Month --
Gifts!)
Raiser. Click on
out more about
Gifts provided
__________ Information from ESET NOD32 Antivirus, version of virus signature
database 3267 (20080714) __________
The message was checked by ESET NOD32 Antivirus.
Message 19
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Power Opti-Miser |
At 12:55 PM 12/10/2009, you wrote:
>
>Yes, indeed it is possible and even money saving to use such a
>device. I was initially puzzled how little technical stuff there
>was, but then I remembered that NASA worked on, published and
>licensed everything in the early 1980s. (Patent + 20 years...hey!).
>
>Power-Miser technology was a big deal then: Google "Power Miser
>NASA" and you will get lots of info. Or search the old NASA archives
>or patents around 1980.
>
>The way the thing works is er...ah...well...I think it might change
>the power factor to match the load. I did a lot of work on power
>factor correction and I can assure you saving money is possible.
>This works only on inductive loads as far as I remember.
>
>The product is real, and so is the money savings. How long it takes
>to pay off the device varies.
THAT IS the big question. Given that improvements
in performance are achieved by improvements in
I-squared*R losses, then savings to be realized
are a function of just how "bad" the "bad" system is.
Most household motor loads tend to be small and
intermittent. Further, these loads have enjoyed
incremental improvements in efficiency over the
years. Bottom line is that if ALL the badness of
a stock system can be compensated for, the savings
are NOT going to be more than a few percent and
that's for devices which contribute to overall
"badness". If these loads are intermittent,
then the savings is multiplied by some duty
cycle that is less than 1.0.
Bottom line is, don't pay much for any such device
without having solid measurements that predict
improvements with an acceptable return on investment.
See:
http://tinyurl.com/3pbopt
P.S. Just because NASA did it does not make it
"golden" . . .
Bob . . .
////
(o o)
===========o00o=(_)=o00o========
< Go ahead, make my day . . . >
< show me where I'm wrong. >
================================
Message 20
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Ammeter help |
Folks;
Thanks to all who replied-all of it useful. However, I need an explanation,
most likely from Bob regarding ammeters.
Bob, I recently purchased rev 12 of the Connection. Page 4-9, last paragraph
says: A zero center, battery ammeter is the most desirable and should be
the first electrical system instrument you install.
Again, on page 7-12, last paragraph, you state: if you plan only one
electrical system instrument, make it a battery ammeter..
With the above being in your book and presumably vetted by yourself, I
became confused when I read in your response to my original post, the
following: Battery ammeters are of limited utility and again the
ammeter offers no useful data for operating the airplane
I need to ask did I completely misinterpret the book? I have Rev 12, which
I am led to believe is the most current (no pun intended), or has your mind
changed substantially since 12 was published? If that is the case, would you
be willing to expound and elucidate on the subject of the necessity of
ammeters in the cockpit? Thanks in advance.
* Keith
* PS The book is great. I did not become aware of it until I attended
an EAA SportAir class where it was highly recommended.
Message 21
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | In-line Battery Fuse; great find |
Good point- I have a problem with the aircraft architecture though; the
kit
manufacturers don't tell you where you can drill holes into structural
members so I had to go around them and through different members. I
didn't
want to drill too many holes or stuff a lot of thinner wires into a
small
hole so I decided to run one fat wire that is well protected, both
electrically and mechanically (much easier to do with one fat wire than
many
thin ones) up to the front.
In this instance the battery bus is not a battery bus as defined, but I
have
been able to get a second battery in at the back of the aircraft without
making too many holes in important places.
Jay
_____
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of
Robert L.
Nuckolls, III
Sent: 21 December 2009 09:46 PM
Subject: RE: AeroElectric-List: In-line Battery Fuse; great find
At 11:35 AM 12/21/2009, you wrote:
I used it to protect a long fat wire from my aux/ 2nd battery which is
located at the back of the aircraft. I had quite a small space to work
in
and hadn=12t thought about protecting the wire in the first place, but
realized that I needed to put some form of protection in. Whilst
searching
for a local ANL type device I came across this and realized that I
wouldn=12t
need to add the ANL base; since there wasn=12t much space to work in
that was
a great relief.
Hmmmm . . . conventional wisdom in TC aircraft calls
for no single always-hot wire to be protected at more
than 5A (breakered) from which I extrapolated 7A (fused).
FAT feeders from a battery normally call for at least
a mini-contactor like . . .