      Most electrical devices that can not be shut off should be on the engine side of
      the firewall.  And if practical, devices that can be shut off should also be
      on the engine side of the firewall.  Look at each component of the electrical
      system and ask yourself, "If this device starts smoking, would I rather have
      it inside of the cockpit or outside, and how will I shut it off?"  When something
      starts smoking inside of the cockpit, it will be difficult to know what device
      it is.  Shutting off the master switch should remove power from almost everything
      inside of the cockpit.
      It would be better to place the following components on the engine side of the
      firewall: Battery, Battery Contactor, Main Battery Bus, Essential Bus Relay, Voltage
      Regulator, Capacitor, Alternator Relay
      Joe
      
      --------