    Time: 01:17:13 AM PST US
    From: "Stuart Hutchison" <stuart@stuarthutchison.com.au>
    Subject: Inflight load return wire size
    G'day Bob, I have an all-metal aircraft without much room for large diameter wires, especially two. I recall reading that it's a good idea to have power and return lines of the same size for small systems, but is it really necessary to have a return wire to the battery of the same size as the starter wire? In other words, I have # 2 AWG CCA fatwire from the battery (down aft) to the starter contactor at the firewall, but I would like to use a # 6 CCA fatwire for inflight currents? I was thinking of grounding the engine to the airframe, but using an # 6 CCA fatwire for return to the battery (insulated from the airframe - to which normal inflight loads [lights, avionics etc] would be connected). Is this idea OK? Cheers, Stu


    Message 2


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 04:57:06 AM PST US
    From: Ben Boatright <benboatright@gmail.com>
    Subject: Inflight load return wire size
    There was a very good article in one of the aviation magazines recently that discussed grounding. The article pointed out that your ground wire should be as large as (or larger) than your positive wire. Keeping the size to those rules should minimize and/or eliminate any ground feedback looping. Ben J. Ben Boatright ----- benboatright@gmail.com ----- Member, AOPA and EAA On Mon, Jun 13, 2011 at 4:13 AM, Stuart Hutchison < stuart@stuarthutchison.com.au> wrote: > stuart@stuarthutchison.com.au> > > G'day Bob, > > I have an all-metal aircraft without much room for large diameter wires, > especially two. I recall reading that it's a good idea to have power and > return lines of the same size for small systems, but is it really necessary > to have a return wire to the battery of the same size as the starter wire? > In other words, I have # 2 AWG CCA fatwire from the battery (down aft) to > the starter contactor at the firewall, but I would like to use a # 6 CCA > fatwire for inflight currents? I was thinking of grounding the engine to > the airframe, but using an # 6 CCA fatwire for return to the battery > (insulated from the airframe - to which normal inflight loads [lights, > avionics etc] would be connected). Is this idea OK? > > Cheers, Stu > >


    Message 3


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 05:48:58 AM PST US
    From: "ROGER & JEAN CURTIS" <mrspudandcompany@verizon.net>
    Subject: Inflight load return wire size
    I have an all-metal aircraft without much room for large diameter wires, especially two. I recall reading that it's a good idea to have power and return lines of the same size for small systems, but is it really necessary to have a return wire to the battery of the same size as the starter wire? Cheers, Stu I own a "tin" T/C aircraft (Cessna Cardinal) and it has the battery in the rear. The negative terminal is connected directly to the airframe with a short cable. There are no other cables going to the negative side of the battery. This seems to work well for Cessna, in that they use the whole airframe as ground reference. When you use this method always be sure that you have a substantial ground strap from the engine to the airframe. Roger


    Message 4


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 07:19:35 AM PST US
    From: "Robert L. Nuckolls, III" <nuckolls.bob@aeroelectric.com>
    Subject: Re: Inflight load return wire size
    At 04:13 AM 6/13/2011, you wrote: ><stuart@stuarthutchison.com.au> > >G'day Bob, > >I have an all-metal aircraft without much room for large diameter wires, >especially two. I recall reading that it's a good idea to have power and >return lines of the same size for small systems, but is it really necessary >to have a return wire to the battery of the same size as the starter wire? >In other words, I have # 2 AWG CCA fatwire from the battery (down aft) to >the starter contactor at the firewall, but I would like to use a # 6 CCA >fatwire for inflight currents? I was thinking of grounding the engine to >the airframe, but using an # 6 CCA fatwire for return to the battery >(insulated from the airframe - to which normal inflight loads [lights, >avionics etc] would be connected). Is this idea OK? I'm not getting a good mental image of your proposed ground system architecture. How long are the wires in question? If you take the approach illustrated in Figure Z-15 View -A- http://www.aeroelectric.com/PPS/Adobe_Architecture_Pdfs/Z15K1.pdf . . . you can consider the option of taking a same-size battery ground wire to the single-point, firewall ground -OR- grounding the battery locally http://aeroelectric.com/Pictures/Grounding/Local_Battery_Grounds_1.jpg 2AWG wire may be somewhat oversized too. Unless you have a really big engine or the battery is a long ways away from the starter, 4AWG wire might be adequate to the task. But I do suggest you review your grounding philosophy in light of suggestions offered in Z-15 and chapter 5 of the 'Connection. Bob . . .


    Message 5


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 09:00:57 PM PST US
    From: "Stuart Hutchison" <stuart@stuarthutchison.com.au>
    Subject: Inflight load return wire size
    Thanks Bob, Yes, I have an IO-540 with the starter about 10 feet ahead of the battery. This configuration is needed A) due to space limitations and B) for weight and balance. I understand the need for a big cable to carry start current and planned to ground this current via the airframe to a local bonding strap next to the battery. However, after start, normal inflight currents will obviously feed via the same big cable to the hot pole of the starter contactor, then to the busses and I would like to ground via a dedicated return to the battery post that is only 6 AWG and is insulated from the airframe. I don't understand why we need an return cable the same size as the starter wire when only 60-70A max is passing through this during flight? Z-15 shows the engine bonding strap connected to a 2 AWG return all the way to the battery, but I propose not to do this, since high currents are only required during start and can be grounded via the airframe for that short period. I would have thought any noise generated during start would be acceptable, because it is temporary? Perhaps different sized power and return wires cause noise regardless of whether they are both quite able to carry the current .. I don't know? Kind regards, Stu -----Original Message----- From: owner-aeroelectric-list-server@matronics.com [mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of Robert L. Nuckolls, III Sent: Tuesday, June 14, 2011 12:01 AM Subject: Re: AeroElectric-List: Inflight load return wire size --> <nuckolls.bob@aeroelectric.com> At 04:13 AM 6/13/2011, you wrote: ><stuart@stuarthutchison.com.au> > >G'day Bob, > >I have an all-metal aircraft without much room for large diameter wires, >especially two. I recall reading that it's a good idea to have power and >return lines of the same size for small systems, but is it really >necessary to have a return wire to the battery of the same size as the starter wire? >In other words, I have # 2 AWG CCA fatwire from the battery (down aft) >to the starter contactor at the firewall, but I would like to use a # 6 >CCA fatwire for inflight currents? I was thinking of grounding the >engine to the airframe, but using an # 6 CCA fatwire for return to the >battery (insulated from the airframe - to which normal inflight loads >[lights, avionics etc] would be connected). Is this idea OK? I'm not getting a good mental image of your proposed ground system architecture. How long are the wires in question? If you take the approach illustrated in Figure Z-15 View -A- http://www.aeroelectric.com/PPS/Adobe_Architecture_Pdfs/Z15K1.pdf . . . you can consider the option of taking a same-size battery ground wire to the single-point, firewall ground -OR- grounding the battery locally http://aeroelectric.com/Pictures/Grounding/Local_Battery_Grounds_1.jpg 2AWG wire may be somewhat oversized too. Unless you have a really big engine or the battery is a long ways away from the starter, 4AWG wire might be adequate to the task. But I do suggest you review your grounding philosophy in light of suggestions offered in Z-15 and chapter 5 of the 'Connection. Bob . . .




    Other Matronics Email List Services

  • Post A New Message
  •   aeroelectric-list@matronics.com
  • UN/SUBSCRIBE
  •   http://www.matronics.com/subscription
  • List FAQ
  •   http://www.matronics.com/FAQ/AeroElectric-List.htm
  • Web Forum Interface To Lists
  •   http://forums.matronics.com
  • Matronics List Wiki
  •   http://wiki.matronics.com
  • 7-Day List Browse
  •   http://www.matronics.com/browse/aeroelectric-list
  • Browse AeroElectric-List Digests
  •   http://www.matronics.com/digest/aeroelectric-list
  • Browse Other Lists
  •   http://www.matronics.com/browse
  • Live Online Chat!
  •   http://www.matronics.com/chat
  • Archive Downloading
  •   http://www.matronics.com/archives
  • Photo Share
  •   http://www.matronics.com/photoshare
  • Other Email Lists
  •   http://www.matronics.com/emaillists
  • Contributions
  •   http://www.matronics.com/contribution

    These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.

    -- Please support this service by making your Contribution today! --