AeroElectric-List Digest Archive

Wed 12/17/14


Total Messages Posted: 11



Today's Message Index:
----------------------
 
     1. 02:51 AM - Re: Wiring dual fuel pumps to single switch (carrollcw)
     2. 07:39 AM - Re: Wiring dual fuel pumps to single switch (Justin Jones)
     3. 07:58 AM - Re: Wiring dual fuel pumps to single switch (John Tipton)
     4. 08:38 AM - Re: Re: Wiring dual fuel pumps to single switch (Charlie England)
     5. 08:58 AM - Re: Re: Wiring dual fuel pumps to single switch (Robert L. Nuckolls, III)
     6. 09:02 AM - Re: Re: Wiring dual fuel pumps to single switch (Jeff Luckey)
     7. 10:11 AM - Re: Re: Wiring dual fuel pumps to single switch (Charlie England)
     8. 05:24 PM - stacking ring terminals on terminal post (Ken Ryan)
     9. 05:38 PM - Re: stacking ring terminals on terminal post (Joe Motis)
    10. 06:03 PM - Re: stacking ring terminals on terminal post (BobsV35B@aol.com)
    11. 10:20 PM - Re: stacking ring terminals on terminal post (Chuck Birdsall)
 
 
 


Message 1


  • INDEX
  • Back to Main INDEX
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 02:51:07 AM PST US
    Subject: Re: Wiring dual fuel pumps to single switch
    From: "carrollcw" <carrollswa@gmail.com>
    Ceengland, if you posted a picture, it's not showing up for me. Read this topic online here: http://forums.matronics.com/viewtopic.php?p=435804#435804


    Message 2


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 07:39:39 AM PST US
    From: Justin Jones <jmjones2000@mindspring.com>
    Subject: Re: Wiring dual fuel pumps to single switch
    If you don=92t want to do it with 2 separate switches, I would suggest looking at a rotary switch. Pay attention to the switch amperage ratings as it may require a relay to drive a fuel pump. Keep in mind that with this option, you will not have the ability to turn both pumps on simultaneously. The 2 switches below may work. http://www.digikey.com/product-detail/en/MRT23-A/360-2376-ND/1046092 <http://www.digikey.com/product-detail/en/MRT23-A/360-2376-ND/1046092> http://www.digikey.com/product-detail/en/HS13Y-D/360-2350-ND/2039688 <http://www.digikey.com/product-detail/en/HS13Y-D/360-2350-ND/2039688> link to the knob for this switch ( http://www.digikey.com/product-detail/en/AT432/360-2366-ND/639088 <http://www.digikey.com/product-detail/en/AT432/360-2366-ND/639088> ) There are many more options out there for rotary switches. Hope this helps Justin > On Dec 16, 2014, at 5:03 PM, carrollcw <carrollswa@gmail.com> wrote: > <carrollswa@gmail.com> > > How can I wire a single dual pole switch to control 2 fuel pumps, only one of which can operate at once with the switch being off bottom, pump 1 middle, pump 2 top. I also need each pump to have an independent power source. I thought I could do it with a 2-1, but I can only get it to go on-off-on. Is there a dual pole switch that will accomplish this? > > > > > Read this topic online here: > > http://forums.matronics.com/viewtopic.php?p=435793#435793 > > > > > > > > > >


    Message 3


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 07:58:36 AM PST US
    Subject: Re: Wiring dual fuel pumps to single switch
    From: John Tipton <jmtipton@btopenworld.com>
    What you want to do is achievable (I believe) with a 2-10, which is an ON-ON -ON - 2 Pole - so wire as you will see here: Ebay: 131380680747 Or 'Steinair' John Sent from my iPad ----x--O--x---- > On 17 Dec 2014, at 03:37 pm, Justin Jones <jmjones2000@mindspring.com> wro te: > > If you don=99t want to do it with 2 separate switches, I would sugge st looking at a rotary switch. Pay attention to the switch amperage ratings as it may require a relay to drive a fuel pump. Keep in mind that with thi s option, you will not have the ability to turn both pumps on simultaneously . > > The 2 switches below may work. > > http://www.digikey.com/product-detail/en/MRT23-A/360-2376-ND/1046092 > > > http://www.digikey.com/product-detail/en/HS13Y-D/360-2350-ND/2039688 link to the knob for this switch ( http://www.digikey.com/product-detail/en/AT4 32/360-2366-ND/639088 ) > > > > There are many more options out there for rotary switches. > > Hope this helps > > Justin > > >> On Dec 16, 2014, at 5:03 PM, carrollcw <carrollswa@gmail.com> wrote: >> m> >> >> How can I wire a single dual pole switch to control 2 fuel pumps, only on e of which can operate at once with the switch being off bottom, pump 1 midd le, pump 2 top. I also need each pump to have an independent power source. I thought I could do it with a 2-1, but I can only get it to go on-off-on. Is there a dual pole switch that will accomplish this? >> >> >> >> >> Read this topic online here: >> >> http://forums.matronics.com/viewtopic.php?p=435793#435793 > > > 3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3 D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D 3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3 D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D 3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3 D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D 3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3 D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D >


    Message 4


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 08:38:29 AM PST US
    From: Charlie England <ceengland7@gmail.com>
    Subject: Re: Wiring dual fuel pumps to single switch
    On 12/17/2014 4:49 AM, carrollcw wrote: > > Ceengland, if you posted a picture, it's not showing up for me. > > No pic; just a reminder that using one switch means a potential single point of failure for both fuel pumps. Might be acceptably low risk, but should be considered.


    Message 5


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 08:58:07 AM PST US
    From: "Robert L. Nuckolls, III" <nuckolls.bob@aeroelectric.com>
    Subject: Re: Wiring dual fuel pumps to single switch
    At 10:38 2014-12-17, you wrote: ><ceengland7@gmail.com> > >On 12/17/2014 4:49 AM, carrollcw wrote: >> >>Ceengland, if you posted a picture, it's not showing up for me. >> >No pic; just a reminder that using one switch means a potential >single point of failure for both fuel pumps. Might be acceptably low >risk, but should be considered. As John mentioned, you can wire a =10 style toggle switch to offer single pole, three position functionality as described in chapter 11 of the 'Connection. Here is one example of this technique. Emacs! A single-pole, three position, center-off will work too . . . but this makes the switch different from all the rest in that OFF is not fully down but mid-position. Charlie's question goes to the notion that if you have two such pumps, then we assume that one must be operational at all times to keep the engine running . . . hence a spare pump. If this is true, then consider the fact that the pump can fail to work for a host of reasons . . . broken wire, bad switch, blown fuse, etc. If one pump circuit goes bad and pops the fuse, then the single failure may take down both pumps. The legacy failure mode effects analysis suggests that the two pumps are best installed as totally separate entities with dedicated switches and power sources. Bob . . .


    Message 6


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 09:02:11 AM PST US
    From: Jeff Luckey <jluckey@pacbell.net>
    Subject: Re: Wiring dual fuel pumps to single switch
    If you're taking a poll... I add my vote to what Charlie said. One switch is a single point of failure - if it fails you could lose both pumps. Just occurred to me: Do you have a situation where you want to prevent both pumps from being on simultaneously? Could use a mechanical interlock between 2 switches if that is the case. -Jeff On Wednesday, December 17, 2014 8:53 AM, Charlie England <ceengland7@gmail.com> wrote: On 12/17/2014 4:49 AM, carrollcw wrote: > > Ceengland, if you posted a picture, it's not showing up for me. > > No pic; just a reminder that using one switch means a potential single point of failure for both fuel pumps. Might be acceptably low risk, but should be considered.


    Message 7


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 10:11:45 AM PST US
    Subject: Re: Wiring dual fuel pumps to single switch
    From: Charlie England <ceengland7@gmail.com>
    On Wed, Dec 17, 2014 at 10:54 AM, Robert L. Nuckolls, III < nuckolls.bob@aeroelectric.com> wrote: > > At 10:38 2014-12-17, you wrote: > > ceengland7@gmail.com> > > On 12/17/2014 4:49 AM, carrollcw wrote: > > > > > Ceengland, if you posted a picture, it's not showing up for me. > > No pic; just a reminder that using one switch means a potential single > point of failure for both fuel pumps. Might be acceptably low risk, but > should be considered. > > > As John mentioned, you can wire a =10 style toggle > switch to offer single pole, three position functionality > as described in chapter 11 of the 'Connection. > > Here is one example of this technique. > > > [image: Emacs!] > > > A single-pole, three position, center-off will > work too . . . but this makes the switch different > from all the rest in that OFF is not fully down > but mid-position. > > Charlie's question goes to the notion that if > you have two such pumps, then we assume that one > must be operational at all times to keep the engine > running . . . hence a spare pump. If this is > true, then consider the fact that the pump > can fail to work for a host of reasons . . . > broken wire, bad switch, blown fuse, etc. > If one pump circuit goes bad and pops the fuse, > then the single failure may take down both > pumps. > > The legacy failure mode effects analysis > suggests that the two pumps are best installed > as totally separate entities with dedicated > switches and power sources. > > Bob . . . > I think he spec'd separate power sources for each pump. But a mechanical failure (cracked housing allowing the switch to fall apart, etc), while admittedly rather low risk for a quality switch, could still take out both pumps.


    Message 8


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 05:24:20 PM PST US
    From: Ken Ryan <keninalaska@gmail.com>
    Subject: stacking ring terminals on terminal post
    What's the accepted practice for stacking ring terminals on a terminal post? Rotax 914 diagram shows 5 wires coming together at a capacitor. What's the best way to make that connection?


    Message 9


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 05:38:22 PM PST US
    Subject: Re: stacking ring terminals on terminal post
    From: Joe Motis <joemotis@gmail.com>
    With new star washers and noalox? 2/3 more than that?? uh uh.. One man's opinion On Wed, Dec 17, 2014 at 5:21 PM, Ken Ryan <keninalaska@gmail.com> wrote: > > What's the accepted practice for stacking ring terminals on a terminal > post? Rotax 914 diagram shows 5 wires coming together at a capacitor. > What's the best way to make that connection? > > * > > > * > >


    Message 10


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 06:03:39 PM PST US
    From: BobsV35B@aol.com
    Subject: Re: stacking ring terminals on terminal post
    Don't know what is being taught these days, but when I went through Aviation Electricians Mate school in 1947 we were told no more than three ring terminals per post. No star washers were to be used because they interfered with good clean contact. Happy Skies, Old Bob Corporal USMC 646659 AEM In a message dated 12/17/2014 7:25:57 P.M. Central Standard Time, keninalaska@gmail.com writes: What's the accepted practice for stacking ring terminals on a terminal post? Rotax 914 diagram shows 5 wires coming together at a capacitor. What's the best way to make that connection?


    Message 11


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 10:20:58 PM PST US
    From: Chuck Birdsall <cbirdsall6@cox.net>
    Subject: Re: stacking ring terminals on terminal post
    Currently being taught is no more than 4 terminals per post. If more connections are needed, then use two posts with a buss bar connecting the two of them - and no more than 3 terminals plus the buss bar per post. Reference is AC 43.13-1B Chapter 11 Sections 8 & 14. See also the section beginning at page 98 in this training manual: http://www.keybridgeti.com/videotraining/manualdl/25827.PDF (which includes a discussion about washers). So, to answer the question directly - in my mind, the standard method would be to terminate all five wires with a ring terminal. Use two adjacent terminal posts on a terminal strip, bridge them with a buss bar and attach two terminals to one post and three to the other. Alternatively you could make a short jumper wire with a terminal on each end, and use it to bridge two posts (you'll wind up with 4 terminals on one post and 3 on the other). *(Wires and/or buss bars sized appropriately for the current load.) Now I'm going to muddy the water a bit. 43.13-1B does say that more than 4 terminals can be placed on a post IF specifically authorized. In the Type-Certificated world that I live in, it's much easier to just wire it to the standard (4 or less per post) than it is to go get approval to do it differently - unless there is an "approved" source (such as an install manual for an STC'd item) telling me to do it differently. Chuck On 12/17/2014 8:02 PM, BobsV35B@aol.com wrote: > Don't know what is being taught these days, but when I went through > Aviation Electricians Mate school in 1947 we were told no more than > three ring terminals per post. No star washers were to be used because > they interfered with good clean contact. > Happy Skies, > Old Bob > Corporal USMC 646659 AEM > In a message dated 12/17/2014 7:25:57 P.M. Central Standard Time, > keninalaska@gmail.com writes: > > What's the accepted practice for stacking ring terminals on a > terminal post? Rotax 914 diagram shows 5 wires coming together at > a capacitor. What's the best way to make that connection? > > * > > * > > * > *




    Other Matronics Email List Services

  • Post A New Message
  •   aeroelectric-list@matronics.com
  • UN/SUBSCRIBE
  •   http://www.matronics.com/subscription
  • List FAQ
  •   http://www.matronics.com/FAQ/AeroElectric-List.htm
  • Web Forum Interface To Lists
  •   http://forums.matronics.com
  • Matronics List Wiki
  •   http://wiki.matronics.com
  • 7-Day List Browse
  •   http://www.matronics.com/browse/aeroelectric-list
  • Browse AeroElectric-List Digests
  •   http://www.matronics.com/digest/aeroelectric-list
  • Browse Other Lists
  •   http://www.matronics.com/browse
  • Live Online Chat!
  •   http://www.matronics.com/chat
  • Archive Downloading
  •   http://www.matronics.com/archives
  • Photo Share
  •   http://www.matronics.com/photoshare
  • Other Email Lists
  •   http://www.matronics.com/emaillists
  • Contributions
  •   http://www.matronics.com/contribution

    These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.

    -- Please support this service by making your Contribution today! --