Subject: | Failing over voltage module |
Rob,
I put your OVM on the bench today. It's trip-point had drifted
UPWARD about 0.5 volts. I re-calibrated it and did a response
test. Its performance is pretty much in the center of
design goals.
Have you run the system (carefully) without the OVM?
Are voltages normal? I"m really mystified about
battery-only tripping. There was nothing in the
performance or physical inspection that would explain
this.
I'd like to update your OVM more toward the response
curves of the next generation OV modules under
development. The original AEC/B&C devices were
pretty fast which made them twitchy in some systems.
If you can wait another 10 days or so, I'll send it
back to you with a slower profile.
Bob . . .
<robnrobinh@comcast.net>
Thanks
I will try to get it out today
-Rob
-----Original Message-----
From: owner-aeroelectric-list-server@matronics.com
[mailto:owner-aeroelectric-list-server@matronics.com] On Behalf Of Robert L.
Nuckolls, III
Sent: Friday, February 13, 2015 10:13 AM
Subject: Re: AeroElectric-List: Failing over voltage module
--> <nuckolls.bob@aeroelectric.com>
At 10:18 2015-02-13, you wrote:
Bob
I purchased 1 of your OVM 2 years ago and have been flying with it for a
year I have a Glastar with a Subaru 2.5L and IR 70 Amp alternator using
Z19RB as a platform I modified the alt field circuit to use the OVM and
installed a relay in the B lead using the Z24 interim The circuit breaker
for the alt field started to randomly trip and during troubleshooting I
found the OVM was tripping even on battery only operations.
Can I send the part back for analysis?
Thanks
-Rob
Absolutely! Please do. It will be repaired/replaced
under our lifetime warranty. It's a rare circumstance
that I can get the carcass back on a fielded failure
to perform.
Box 130, Medicine Lodge, KS 67104-0130
Bob . . .
Bob . . .
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Failing over voltage module |
Rob,
If you can wait another 10 days or so, I'll send it
back to you with a slower profile.
Bob . . .
P.S. I would simply replace the one you sent
me but yours is an older configuration with
the miniature pot . . . and I don't have any
newer ones built. If the wait doesn't put
you in a bind, the upgraded old unit is the
better way to go.
Bob . . .
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Failing over voltage module |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Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|