Today's Message Index:
----------------------
1. 07:37 AM - Re: Re: Starter Contactors (Robert L. Nuckolls, III)
2. 09:02 AM - Dead battery (JOHN TIPTON)
3. 03:21 PM - Re: Starter Contactors (reaper)
4. 05:12 PM - Re: Starter Contactors (user9253)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Starter Contactors |
>
>
>Something along these lines?
>Why the anl60? Starter current could blow it, and if the start
>contactor is next to the master contactor, no protection is needed.
>
The excerpt is truncated . . . the ANL60
is in the altenrator b-lead feeder. A 2AWG
(or 4AWG) wire to the battery contactor
from the same terminal is missing.
Bob . . .
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Hi Guys
Can you help, my son left his ignition on (his CBR 600 Honda motorbike) the six
month old AGM battery is now dead, the 'conditioner' charger indicates fully
charged and maintaining - is the battery recoverable or now junk
Regards - John
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=465333#465333
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Starter Contactors |
Is the excerpt the right way to detect voltage between "I" and the starter?
That is to say, three connects to "I",
Diode to ground
LED to ground
Starter motor solenoid
Will the disconnect surge still flow via the diode rather than the LED if the LED
resistance is sufficient?
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=465349#465349
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Starter Contactors |
Yes, induced current will only flow through the arc suppression diode. No induced
current will flow through the LED because the LED will be reversed biased.
The arrows on the arc suppression diode and the LED point in opposite directions.
The value of the resistor is irrelevant because any induced voltage has
the wrong polarity to illuminate the LED.
> Will the disconnect surge still flow via the diode rather than the LED if the
LED resistance is sufficient?
--------
Joe Gores
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=465357#465357