At 02:35 PM 11/24/2017, you wrote:
>
>Is it acceptable to use cb's, fuses or limiters in place of the fuse
>links from the stby alternator, main bus to master and the alternate
>essential bus feed? Also is it ok to use 1 amp fuses in place of
>fuse links from the shunts on a G3X system?
>
>
Sure. Fusible links are simply a low cost, lower parts
count, convenient substitute for the LONG TIME CONSTANT
current limiter. Fusible links and current limiters target
the battery-driven, hard fault condition.
For your purposes, you can replace ANY fusible link
shown in the drawings with a fuse or circuit breaker
but I suggest that it only adds to cost and labor.
But it's not 'unacceptable'.
I would avoid using fuses lower than 3A for
mechanical robustness concerns . . . in fact,
for airplanes wired with nothing smaller than
22AWG, a 5A fuse is a practical lower limit
for fuse selection.
Bob . . .
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | 1A Slow Blow Fuse |
Bob,
In a recent message, you wrote: " I would avoid using fuses lower than 3A
for mechanical robustness concerns."
I am installing an MGL backup ASI+altimeter and the installation
instructions call for a 1A slow blow fuse. I bought a glass tube fuse and
an inline holder.
I do remember what you have written (many times!) about fuses protecting
the wires but opted to follow the manufacturer's instructions. I would love
to hear your thoughts about this situation.
-- Art Z.
--
https://CheerfulCurmudgeon.com/
*"If I am not for myself, who is for me? And if I am only for myself, what
am I? And if not now, when?" Hillel*
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: 1A Slow Blow Fuse |
1A slow blow sounds oxymoronic to me=2E=2E=2E
Charlie
On Nov 25, 2017,
9:37 PM, at 9:37 PM, Art Zemon <art@zemon=2Ename> wrote:
>Bob,
>
>In a rece
nt message, you wrote: " I would avoid using fuses lower than
>3A
>for mech
anical robustness concerns=2E"
>
>I am installing an MGL backup ASI+altimet
er and the installation
>instructions call for a 1A slow blow fuse=2E I bou
ght a glass tube fuse
>and
>an inline holder=2E
>
>I do remember what you h
ave written (many times!) about fuses
>protecting
>the wires but opted to f
ollow the manufacturer's instructions=2E I would
>love
>to hear your though
ts about this situation=2E
>
> -- Art Z=2E
>
>--
>https://CheerfulCurmu
dgeon=2Ecom/
>
>*"If I am not for myself, who is for me? And if I am only f
or myself,
>what
>am I? And if not now, when?" Hillel*