Today's Message Index:
----------------------
1. 08:30 AM - Re: Testing Battery Capacity... (Robert L. Nuckolls, III)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Testing Battery Capacity... |
At 08:44 PM 1/13/2018, you wrote:
>I said: "I've yet to test the battery I replaced it with."
>
>Bob N. said: "Would like to see that data . . ."
>
>I don't recall for sure but my best guess is the
>"new" (bought Dec '16) battery
>is a Duracell Ultra 18Ah. =C2 (whatever Batteries Plus was had as their
generic
>18AH AGM). I didn't removed it from the Longeze when I tested it today.
>It was 48 degreesF at the start of the test (and a few degrees colder at
>the end) and with my 3 Ohm load it ran for 3hr and 14 minutes.
Interesting. Okay 11.5v average/3 ohms yields ~3.8A for 3.25
hours is 12.4 A.H. According to the Enersys data on a PC680,
the new battery supports about 4A for 3.2 hours
Emacs!
It would appear that your test article is pretty healthy. The only other
variable is load dump ability. Given the cap-check data, I'd bet
the load dump numbers are good too.
Bob . . .