Today's Message Index:
----------------------
1. 08:05 AM - Re: Re: Z-13/8 inquiry (Robert L. Nuckolls, III)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Z-13/8 inquiry |
At 08:07 PM 2/5/2018, you wrote:
>
>More Questions.
>
>I took a screen shot of a small part of the Z-10/8 wiring
>diagram. Focus with me on the bus tie between the Main Power Bus
>and the Endurance Bus. The Endurance Bus gets its primary feed from
>the Main Power bus thru the Diode, and its typical of the diagrams in AEC.
>
>This circuit is unprotected....no fuse, no circuit breaker, no
>current limiter, no fuse link. I guess thats ok., but seems
>abnormal. Can I have some feedback?
The e-bus and main bus should be located close to each
other. The wires that connect the normal feedpath diode
are short. Risk to those wires is nil. No protection
warranted.
>I argue with myself that its because we want a reliable E-bus feed.
You have two feed paths . . . loss of one is unlikely,
loss of both is exceedingly unlikely.
> Then I see that the diagrams in AEC fuse the Alternate Feed from
> the Hot Battery Bus.
That's a long feeder that's not so free of risk.
Bob . . .