Today's Message Index:
----------------------
1. 06:35 AM - Re: Forest of Tabs in Multiple Locations (Robert L. Nuckolls, III)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Forest of Tabs in Multiple Locations |
At 11:29 AM 3/19/2021, you wrote:
>
>A fellow RV-7 builder has a B&C forest of tabs located on the pilot
>side of the firewall with battery ground attaching on the hot side.
>
>They also have a small cluster of tabs on the sub panel. This group
>of tabs is electrically bonded to the sub panel and has a 14awg wire
>connecting the sub panel tabs to the firewall tabs. This cluster on
>the sub panel is for the avionics grounds.
>
>Should the sub panel tabs be isolated from the sub panel or is it OK
>the way it is?
The 14AWG jumper adds no value in a metal
airplane. I can be deleted and avionics grounded
at the sub-panel.
Bob . . .
Un impeachable logic: George Carlin asked, "If black boxes
survive crashes, why don't they make the whole airplane
out of that stuff?"