Today's Message Index:
----------------------
1. 05:23 PM - Re: Z 16 question (William Daniell)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Z 16 question |
Bob
thanks.
Rotax regulator fitted with old style OVP at the relay end...everything
stable and radio noise gone.
I am sending the AVC1 to bandc
Will
William Daniell
LONGPORT
+1 786 878 0246
On Mon, Dec 19, 2022 at 4:46 PM Robert L. Nuckolls, III <
nuckolls.bob@aeroelectric.com> wrote:
> At 07:18 PM 12/18/2022, you wrote:
>
> I am refitting my old voltage regulator after a failure of the bandc one
I
> installed a year ago.=C3=82 =C3=82 The bandc has built in ovp.=C3=82 I
am assuming that
> this is a manufacturing defect ...i had a very early version.
>
> I have ordered a new one.
>
>
> Take a look at the B&C current offering for
> PM rectifier/regulators at:
>
> https://tinyurl.com/2lr4u6o6
>
> The old regulators (including the last Rotax I saw)
> are 3 decades old technology.
>
> The AVC1 R/R has ov protection plus alternator control
> relay built in. Everything in one box and 30 years
> 'younger'.
>
>
> Meantime i am refitting a rotax regulator and I am also refitting my old
> ovp/relay
>
> The z 16 shows the ovp from master to ground at the panel.
>
> Could I install the ovp at the relay end to ground at the firewall?
>
>
> Yes
>
>
> Bob . . .
>
> Un impeachable logic: George Carlin asked, "If black boxes
> survive crashes, why don't they make the whole airplane
> out of that stuff?"
>
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|