Subject: | Ground Block Mounting questions |
I am building an RV7 and have the BandC GB48 48 tab ground block. It appears to
have only one pass thru bolt for mounting (pic attached). My questions are:
1. Do people recommend soldering the entire piece ( 0.04 flat brass stock ) to
the stainless steel firewall for mounting and good conductivity, in addition to
the pass thru bolt provided? If so, just regular solder with flux? And a whopping
big iron needed for the heat sink issues?
2. Any reason not to just rivet the brass plate to the firewall? Like dissimilar
metal issues between copper and stainless steel?
3. I assume I can flip the bolt direction of the attached picture, to have the
pass through bolt head on the interior cockpit side with the tabs, and the protruding
stud on the engine side of the firewall, near the battery ground post,
so a short ground cable can run from the battery to this ground block stud.
But in searching for application pics, I dont see this. I see most people just
ground the battery negative post to a nearby firewall bolt hole, Not directly
to the ground block. Why not? Package issues? Servicing issues?
--------
Jeff
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=510975#510975
Attachments:
http://forums.matronics.com//files/groundblock_gb48_911.jpeg
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Ground Block Mounting questions |
On Thu, Jun 15, 2023 at 2:03=AFPM jcohen@post.com <jcohen@post.com> w
rote:
> jcohen@post.com>
>
> I am building an RV7 and have the BandC GB48 48 tab ground block. It
> appears to have only one pass thru bolt for mounting (pic attached). My
> questions are:
>
> 1. Do people recommend soldering the entire piece ( 0.04=9D flat br
ass stock
> ) to the stainless steel firewall for mounting and good conductivity, in
> addition to the pass thru bolt provided? If so, just regular solder with
> flux? And a whopping big iron needed for the heat sink issues?
> 2. Any reason not to just rivet the brass plate to the firewall? Like
> dissimilar metal issues between copper and stainless steel?
> 3. I assume I can flip the bolt direction of the attached picture, to hav
e
> the pass through bolt head on the interior cockpit side with the tabs, a
nd
> the protruding stud on the engine side of the firewall, near the battery
> ground post, so a short ground cable can run from the battery to this
> ground block stud. But in searching for application pics, I don=99t
see this.
> I see most people just ground the battery negative post to a nearby
> firewall bolt hole, Not directly to the ground block. Why not? Package
> issues? Servicing issues?
>
> --------
> Jeff
>
>
> I suspect that the tabs would start falling off the plate before you
could get it hot enough to solder to something else. Do you have room on
the other end to drill for a smaller bolt; say an AN3? I home-brewed my
tabs plate, and used a bolt at each end to attach it. The primary bolt is a
longer 5/16" from the plumbing isle of the local Ace Aviation supply ( ;-)
) that I ran through the plate, then firewall, nutted, then used as my FWF
ground stud, like you're describing.
FWIW...
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Z101 switch state question: engine and main |
bus shutdown
On Tue, Jun 13, 2023 at 3:28=AFPM Robert L. Nuckolls, III <
nuckolls.bob@aeroelectric.com> wrote:
> Bob,
> For me, the critical factor here is not independent control of the
> battery; it's that the aux alternator is effectively playing the role of
> the internal generation system of a magneto; supplying electrical energy
to
> the engine, even when the entirety of the airframe is made electrically
> 'cold'. As drawn in Z101:
>
>
> What accessories will be fed from your
> proposed aux bus loads that you would
> not want to power in combination with
> keeping the engine running?
>
> Electrically induced smoke in cockpit is
> an exceedingly tiny risk. So aside from
> finding yourself on short-final-to-the-rocks,
> when would you expect to want the electrical
> system completely 'cold'? This condition
> would call for the engine to be shut down
> as well.
>
> Muscle memory? When did this replace a
> well conceived and practiced check
> list? When faced with a need to reduce
> energy consumption in a Z101 architecture,
> I would think that line item 1 would be to
> switch ENGINE BUS ALTERNATE source feeder ON.
> Item 2 would be to switch AUX BUS ALT FEEDER
> and AUX ALTERNATOR to ON. 3. Set master switch
> to OFF to kill any potential main alternator field
> drain and eliminate battery contactor drain.
>
> snipped
>
Muscle memory (or no memory at all) tends to replace just about everything
if we're stressed. ;-)
I don't necessarily disagree with any of the technical points, but most of
us are going to revert to decades-old training & practices when we're not
absolutely certain what we need to do. And beyond that, I know of a
real-world case of someone running an alternative engine to electrical
exhaustion when his alternator switch got bumped off. Obviously that should
never happen, but moving to an alternative engine after decades of flying
mags makes it easier to overlook stuff that wouldn't have mattered with a
standard engine configuration.
Different strokes, I suppose.
Charlie
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Ground Block Mounting questions |
Hello Jeff,
1. Don't solder it to firewall.=C2- A bolted connection is the correct wa
y to attach it (PS, you can't solder stainless)
2. Don't rivet it either.=C2- The typical method is to thru bolt it using
2 big brass bolts.=C2- 5/16 or 3/8 bolts.
3. What you said.=C2- Battery neg directly to one of the big grounding-bl
ock mounting-bolts with a big wire.=C2- From that bolt I would also run t
he engine grounding strap/cable directly to the block, usually near the sta
rter motor.
Jeff LuckeyKCMA On Thursday, June 15, 2023 at 12:06:33 PM PDT, jcohen@po
st.com <jcohen@post.com> wrote:
m>
I am building an RV7 and have the BandC GB48 48 tab ground block. It appear
s to have only one pass thru bolt for mounting (pic attached). My questions
are:
1. Do people recommend soldering the entire piece ( 0.04=C3=A2=82=AC=EF
=BD flat brass stock ) to the stainless steel firewall for mounting and
good conductivity, in addition to the pass thru bolt provided? If so, just
regular solder with flux? And a whopping big iron needed for the heat sink
issues?
2. Any reason not to just rivet the brass plate to the firewall? Like dissi
milar metal issues between copper and stainless steel?
3. I assume I can flip the bolt direction of the attached picture, to have
the pass through bolt head on the interior cockpit side with the tabs,=C2
- and the protruding stud on the engine side of the firewall, near the ba
ttery ground post, so a short ground cable can run from the battery to this
ground block stud. But in searching for application pics, I don=C3=A2
=82=AC=84=A2t see this. I see most people just ground the battery negati
ve post to a nearby firewall bolt hole, Not directly to the ground block. W
hy not? Package issues? Servicing issues?
--------
Jeff
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=510975#510975
Attachments:
http://forums.matronics.com//files/groundblock_gb48_911.jpeg
-
S -
WIKI -
-
=C2- =C2- =C2- =C2- =C2- -Matt Dralle, List Admin.
Message 5
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Ground Block Mounting questions |
My homemade solution is much like what Charlie described, but with one brass bolt
in the center. I plan to use a single small bolt elsewhere on the plate just
to prevent rotation.
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=510979#510979