Today's Message Index:
----------------------
1. 07:02 AM - Re: oil thermostat installation (Thom Riddle)
2. 10:16 AM - Re: Re: oil thermostat installation (Hugh)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: oil thermostat installation |
Upon finishing the gearbox inspection yesterday, I checked the connections to the
Perma-Coll oil thermostat. The connections are thus:
C1 and C2 connect to the oil cooler, flow direction irrelevant.
E1 connects to "OUT" port on the oil sump(tank).
E2 connects to the inlet side of the oil pump.
So, the oil flows from the sump(tank) to the E1 port on the oil thermostat, and
then through the thermostat and oil cooler at variying ratios depending upon
temperature, then to the suction side of the oil pump via port E2 on the Perma-Cool.
--------
Thom in Buffalo
N221FA Allegro 2000 912UL
N197BG FS1/447
--------------------
Finance is the art of passing money from hand to hand until it finally disappears.
- Robert W. Sarnoff
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=151292#151292
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: oil thermostat installation |
Thom:
Thanks again for the clarification.
Hugh
-----Original Message-----
From: owner-allegro-list-server@matronics.com
[mailto:owner-allegro-list-server@matronics.com] On Behalf Of Thom Riddle
Sent: Sunday, December 09, 2007 10:02 AM
Subject: Allegro-List: Re: oil thermostat installation
Upon finishing the gearbox inspection yesterday, I checked the connections
to the Perma-Coll oil thermostat. The connections are thus:
C1 and C2 connect to the oil cooler, flow direction irrelevant.
E1 connects to "OUT" port on the oil sump(tank).
E2 connects to the inlet side of the oil pump.
So, the oil flows from the sump(tank) to the E1 port on the oil thermostat,
and then through the thermostat and oil cooler at variying ratios depending
upon temperature, then to the suction side of the oil pump via port E2 on
the Perma-Cool.
--------
Thom in Buffalo
N221FA Allegro 2000 912UL
N197BG FS1/447
--------------------
Finance is the art of passing money from hand to hand until it finally
disappears.
- Robert W. Sarnoff
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=151292#151292
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|