Today's Message Index:
----------------------
1. 11:48 PM - Fw: Aerospace Logic New Instrument Models (YOURTCFG@aol.com)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Fwd: Aerospace Logic New Instrument Models |
--> Commander-List message posted by: YOURTCFG@aol.com
From: "Aerospace Logic Inc." <sales@aerospacelogic.com>
Subject: Aerospace Logic New Instrument Models
------_PartID_114397179733146
------_PartID_114397179733146
<IMG src"http://www.aerospacelogic.com/images/email/LogoFuel.jpg" border0>
<IMG src"http://www.aerospacelogic.com/images/email/NPR.jpg" border0>
New Instrument
Models
Aerospace Logic Inc. is pleased to announce the release of three
new variants of the popular FL-100-R Dual Fuel Level indicator. These new
products enhance sender response for lower resistance senders and greatly
simplify the calibration process. Typical install and calibration time is
reduced by at least 50% by using these new products. They are identified as
follows:
FL-100-R(44)
For use with senders that have a maximum resistance of no
more than 44 Ohms
FL-100-R(67)
For use with senders that have a maximum resistance of no
more than 67 Ohms
FL-100-R(109)
For use with senders that have a maximum resistance of no
more than 109 Ohms
The existing FL-100-R instrument supports senders with maximum resistance
of 300 Ohms but has been updated with the new Ver. 2.05 calibration software
that is standard in the new instrument models. When purchasing the
FL-100-R instrument, choosing the appropriate model that yields the best
performance is advised. Keep in mind that the FL-100-R (0-300 Ohm, standard,
generic instrument will work for all sender ranges), the new model ranges will
substantially improve the efficiency of the calibration process. For example: if
the target fuel sender had an operating resistance of 0-35 Ohms all instruments
would be suitable for this installation but the FL-100-R(44) would provide the
best calibration performance. For an aircraft with 35 to 270 Ohm senders the
FL-100-R instrument is the only applicable product and will provide the best
calibration performance. In all cases operational accuracy, performance and
specifications remain unchanged.
New Calibration Algorithms and
Process
The entire calibration process has been redefined for all FL-100
models and now offers the following significant improvements:
Unknown Tank Size Calibration
It is no longer a requirement=20to
know the tank size or the maximum indicating capability of your fuel
sender/tank configuration. Once the tank has been filled or the sender reaches
its maximum reporting point, the calibration process can be concluded and=20the
maximum fuel quantity as well as maximum sender reporting capability is
automatically computed and programmed into the instrument.
One Pass Calibration
Tank calibration can now be concluded with
one single fill/calibrate cycle. The previous requirement to recalibrate the
tank if the full capacity was not reached is now eliminated by the new tank
capacity computation algorithm.
Detailed Sender Error Reporting
In depth diagnostic and
reporting functions have now been integrated into the calibration software
that will allow the pinpointing of sender and calibration problems. Error
resolution details are now included as part of the installation manual.
Critical Point Condition Reporting
FAR's define specific
functional points for fuel level indicating systems. The calibration routines
now include error and diagnostic reporting systems to confirm that the target
fuel senders meet the requirements of the FAR's. Where they do not, problem
sources are identified and resolution options are included in the
installations manual.
Non-Similar Tank Sizes
As a result of all these changes to the
calibration system, the instrument is now able to support different fuel tank
quantities for the two tanks. This is of specific significance as it relates
to sender response where previously the sender ranges had to be identical. The
identical requirement still remains at the zero fuel level (a FAR
requirement). In addition the instrument can now be used for different size
belly and auxiliary tanks.
All instruments with the revised calibration software systems are identified
with a v2.05 message on startup and a Rev 4 or greater on the identification
tag.
CALL AND ORDER NOW=20TO
RECEIVEA SPECIAL DISCOUNT ON ALL INSTRUMENTS!!!
905-569-3887
------_PartID_114397179733146--
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|