Today's Message Index:
----------------------
1. 02:06 PM - Sump Drain valve for 680F (Randy Dettmer, AIA)
2. 03:20 PM - Re: Sump Drain valve for 680F (Moe-rosspistons)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Sump Drain valve for 680F |
The last time I drained fuel from the center tank sump, the valve did not
close completely and fuel continued to drip overboard. After opening and
closing several times, the dripping stopped. I have not opened the valve
since, for fear of it sticking open again. Has anybody experienced this
situation..?? I was unable to identify the valve in my parts manual. Is it
the same in all Commanders..?? I may need a replacement valve. Anyone have
one..?? Thanks.
Randy Dettmer, AIA
680F / N6253X
Dettmer Architecture
663 Hill Street
San Luis Obispo, CA 93405
805 541 4864 / Fax 805 541 4865
www.dettmerarchitecture.com
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Sump Drain valve for 680F |
Randy,
This valve (the twist valve that you access through the small door under
the wing) looks suspiciously like the Eelco valve that I used to shut
off the fuel in my D Altered 57 Chevy. Drag Car equipped with early
Hilborn Injectors in about 1972. Meaning that it was military surplus.
Most likely the valve needs to be removed and new "o" rings installed.
You are correct that the valve is not listed in the Commander parts
book, which is a very good thing..........................
Regards.
Moe
N680RR
Proud Holder of The Golden Pedal Award
From: Randy Dettmer, AIA
Sent: Saturday, May 23, 2009 1:57 PM
Subject: Commander-List: Sump Drain valve for 680F
The last time I drained fuel from the center tank sump, the valve did
not close completely and fuel continued to drip overboard. After
opening and closing several times, the dripping stopped. I have not
opened the valve since, for fear of it sticking open again. Has anybody
experienced this situation..?? I was unable to identify the valve in my
parts manual. Is it the same in all Commanders..?? I may need a
replacement valve. Anyone have one..?? Thanks.
Randy Dettmer, AIA
680F / N6253X
Dettmer Architecture
663 Hill Street
San Luis Obispo, CA 93405
805 541 4864 / Fax 805 541 4865
www.dettmerarchitecture.com
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|