Engines-List Digest Archive

Sun 08/05/07


Total Messages Posted: 2



Today's Message Index:
----------------------
 
     1. 12:12 PM - Oil thermostatic by pass valves. (Walt Murphy)
     2. 01:30 PM - Re: Oil thermostatic by pass valves. (Gene Smith)
 
 
 


Message 1


  • INDEX
  • Back to Main INDEX
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 12:12:45 PM PST US
    From: Walt Murphy <waltmurphy@charter.net>
    Subject: Oil thermostatic by pass valves.
    Question: Does anyone know just exactly how far the vern a therm ( by pass valve ) is supposed to stretch when at temperature? We have an oil temp problem and the by pass valve was replaced. ( ECI PMA replacement part ) . It did not solve the problem. Looking at the NEW part there was NO wear mark at all on the seating face of the valve. Placing it into a cup of boiling water it grew 0.107 from the ambient length. I also measured another ( old Lycoming part ) it grew 0.180 Also when I look at the ECI part in the oil filter adapter housing , it sits deeper than the Lycoming part. ( It appears that the ECI part would need to "grow" over 1/4 inch to make contact compared to maybe 1/16 to 1/8 inch on the Lycoming part. Thanks, Walt


    Message 2


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 01:30:54 PM PST US
    From: "Gene Smith" <esmith6@satx.rr.com>
    Subject: Re: Oil thermostatic by pass valves.
    Walt...................Lycoming Engines, 652 Oliver St., Williamsport, Pa. 17701.........570-323-6181..........Ask for "SUPPORT CENTER." 0800-1700 EDT, Mon-Fri...I'm sure the engineers will have an answer for you.....................................www.lycoming.textron.com/index.jsp CHEERS!!!! and good luck.............Gene Smith. ----- Original Message ----- From: "Walt Murphy" <waltmurphy@charter.net> Sent: Sunday, August 05, 2007 2:09 PM Subject: Engines-List: Oil thermostatic by pass valves. > > Question: > > Does anyone know just exactly how far the vern a therm ( by pass valve ) > is supposed to stretch when at temperature? > > We have an oil temp problem and the by pass valve was replaced. ( ECI > PMA replacement part ) . It did not solve the problem. Looking at the > NEW part there was NO wear mark at all on the seating face of the valve. > Placing it into a cup of boiling water it grew 0.107 from the ambient > length. I also measured another ( old Lycoming part ) it grew 0.180 > > Also when I look at the ECI part in the oil filter adapter housing , it > sits deeper than the Lycoming part. ( It appears that the ECI part would > need to "grow" over 1/4 inch to make contact compared to maybe 1/16 to > 1/8 inch on the Lycoming part. > > Thanks, > Walt > >




    Other Matronics Email List Services

  • Post A New Message
  •   engines-list@matronics.com
  • UN/SUBSCRIBE
  •   http://www.matronics.com/subscription
  • List FAQ
  •   http://www.matronics.com/FAQ/Engines-List.htm
  • Web Forum Interface To Lists
  •   http://forums.matronics.com
  • Matronics List Wiki
  •   http://wiki.matronics.com
  • 7-Day List Browse
  •   http://www.matronics.com/browse/engines-list
  • Browse Engines-List Digests
  •   http://www.matronics.com/digest/engines-list
  • Browse Other Lists
  •   http://www.matronics.com/browse
  • Live Online Chat!
  •   http://www.matronics.com/chat
  • Archive Downloading
  •   http://www.matronics.com/archives
  • Photo Share
  •   http://www.matronics.com/photoshare
  • Other Email Lists
  •   http://www.matronics.com/emaillists
  • Contributions
  •   http://www.matronics.com/contribution

    These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.

    -- Please support this service by making your Contribution today! --