SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: trimming fuselage upper moulding firewall flange |
On Aug 1, 2014, at 7:14 AM, Rowland Carson <rowlandcarson@gmail.com>
wrote:
> There doesn't seem to be any explicit advice about trimming that area
in the manual, but fig 8 on page 23M-5 seems to suggest that a 25mm
flange is OK, since the BID tapes it illustrates going across the joint
are only 50mm wide.
Rowland=85IMHO, it is a real stretch to interpret fig. 8 as "a
suggestion that a 25 mm flange is OK=94=85personally, I would not
consider trimming the top fuselage flange at the firewall for even a
nanosecond, given its obvious contribution to the rigidity to the
airframe=85I read fig. 8 as an un-dimensioned illustration of the
relationships of the various components at this critical
intersection=85nothing more...Fred
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: trimming fuselage upper moulding firewall flange |
Amen to that, David Joyce, G-XSDJ
On Sat, 2 Aug 2014 07:32:42 -0700
Fred Klein <fklein@orcasonline.com> wrote:
>
> On Aug 1, 2014, at 7:14 AM, Rowland Carson
><rowlandcarson@gmail.com> wrote:
>
>> There doesn't seem to be any explicit advice about
>>trimming that area in the manual, but fig 8 on page 23M-5
>>seems to suggest that a 25mm flange is OK, since the BID
>>tapes it illustrates going across the joint are only 50mm
>>wide.
>
> RowlandIMHO, it is a real stretch to interpret fig. 8
>as "a suggestion that a 25 mm flange is OKpersonally, I
>would not consider trimming the top fuselage flange at
>the firewall for even a nanosecond, given its obvious
>contribution to the rigidity to the airframeI read fig.
>8 as an un-dimensioned illustration of the relationships
>of the various components at this critical
>intersectionnothing more...Fred
>
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Fwd: Resin dispenser. free to good home |
I have been tidying out my garage and came across my old Michael engineering resin
dispenser, used in my build. If any builder could use it I will be happy to
send it for the price of the postage. May need freeing off a bit as it hasn't
been used for a while.
http://www.michaelengineering.com/Pumps/Manual/StickyStuffDispenser/
Richard Iddon. G-RIXS
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: trimming fuselage upper moulding firewall flange |
Hi Rowland,
Will you have another can of Redux at the redy, borrowed or bought, just in case
you need a little more?not a good time to find out you need more, and have to
scrape a whole can off, and throw it in the bin for the sake of 5-10% more.
Something to ponder.
Regards
Tony Renshaw
Sent from my iPad
> On 2 Aug 2014, at 12:14 am, Rowland Carson <rowlandcarson@gmail.com> wrote:
>
>
> I've had the pre-bond inspections all signed off and am hoping to organise a
Redux posse soon to glue the fuselage top on.
>
> I note that the forward end flange which fits against the firewall is quite generous
compared to the flanges elsewhere, which are between 35mm & 50mm wide.
I'm intending to trim the flange for the firewall joint back to about 40mm, but
thought I'd check to see if anyone thought that is a bad idea. There doesn't
seem to be any explicit advice about trimming that area in the manual, but fig
8 on page 23M-5 seems to suggest that a 25mm flange is OK, since the BID tapes
it illustrates going across the joint are only 50mm wide.
>
> Any thoughts welcome.
>
> in friendship
>
> Rowland
>
>
>
>
>
>
>