Today's Message Index:
----------------------
1. 01:32 AM - Re: Stall Warner - switch problems (jonathanmilbank)
2. 04:46 AM - Re: Stall Warner - switch problems (davidjoyce@doctors.org.uk)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Stall Warner - switch problems |
Hi Clive,
My stall warner switch has worked reliably for about 15 years, so my memory of
an initial problem is vague. But your "it is closed/the horn sounds once the a/c
is back on the ground/at zero to low forward speed" rings a bell in my head.
I'm my case it was caused, as far as I can remember, by the air pressure tube/s
being fitted to the wrong spigot/s. Simply swapping the tube/s around cured it.
The adjustment screw in the middle needed little or no turning to get the warner
to activate at 5 knots above stall.
Jonathan
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=470186#470186
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Stall Warner - switch problems |
I fixed it by fitting a Smartass, easily heard via headset & impossible
to ignore, neither of which can be said for stall warner even when
working - which sounds as a very distant minor squeak using modern
headsets!
Regards, Davi (Joyce, GXSDJ)
On 2017-06-16 22:17, clivesutton wrote:
>
> I have the 0.072 PSI/5mBar/500Pascal Vacuum stall warner switch supplied by Europa
fitted in G-YETI (RS Components part No 317-443) but I'm struggling to get
it to work correctly - despite changing the switch for a new one today.
>
> The first switch would not reliably make contact at the stall warn speed (light/intermittent
squeaks at varying speeds) and whilst the other does work more
reliably it is closed/the horn sounds once the a/c is back on the ground/at zero
to low forward speed.
>
> Has anyone else had this problem and can share how they fixed it or can anyone
recommend another more reliable switch (based on personal experience in use)
please? The pipe between switch and the hole just below the wing leading edge
is correctly connected to the NO port A btw.
>
> All inputs appreciated
>
> Clive S
>
> Read this topic online here:
>
> http://forums.matronics.com/viewtopic.php?p=470177#470177 [1]
>
Links:
------
[1] http://forums.matronics.com/viewtopic.php?p=470177#470177
[2] http://www.matronics.com/Navigator?Europa-List