Today's Message Index:
----------------------
1. 03:39 AM - Re: New ignition modules (spcialeffects)
2. 11:35 AM - Re: New ignition modules (tennant)
3. 12:22 PM - Re: Re: New ignition modules (Peter Rees)
4. 03:15 PM - Re: Re: New ignition modules (William Daniell)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: New ignition modules |
Hi Martin. I have the same 4 pin modules and had a similar problem. When I changed
to one of the circuits my 914 ran rough. I bought the new ignitech modules
and still had the same issue. The only way I rectified it was to buy new rotax
modules. What I did find out during my investigations was that the ignition
modules are wired up to the coils differently for a rotax 912 then a 914. On a
912 A module runs 2 upper and 2 lower plugs but on the 914 module A runs all
the top plugs and B runs all the bottom.
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=503523#503523
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: New ignition modules |
Martin,
I had the same problem. Bought expensive new modules and after a lot of messing
about - it was the stator that was defective!!
Barry
--------
Barry Tennant
D-EHBT
At EDLM - Germany
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=503524#503524
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: New ignition modules |
Swap the red wires over - if the problem changes from L to R (or R to L) - stator
fault. Also try the same on the pickups.
Process of Elimination
Peter
> On 14 Oct 2021, at 19:42, tennant <barrington.tennant@gmail.com> wrote:
>
>
> Martin,
> I had the same problem. Bought expensive new modules and after a lot of messing
about - it was the stator that was defective!!
>
> Barry
>
> --------
> Barry Tennant
> D-EHBT
> At EDLM - Germany
>
>
>
>
> Read this topic online here:
>
> http://forums.matronics.com/viewtopic.php?p=503524#503524
>
>
>
>
>
>
>
>
>
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: New ignition modules |
Me too ...except it was the ground wire
Will
William Daniell
LONGPORT
+1 786 878 0246
On Thu, Oct 14, 2021 at 2:39 PM tennant <barrington.tennant@gmail.com>
wrote:
> >
>
> Martin,
> I had the same problem. Bought expensive new modules and after a lot of
> messing about - it was the stator that was defective!!
>
> Barry
>
> --------
> Barry Tennant
> D-EHBT
> At EDLM - Germany
>
>
> Read this topic online here:
>
> http://forums.matronics.com/viewtopic.php?p=503524#503524
>
>
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|