Page 24 of the Installation Manual for the 3300, last sentence says "Exhaust Gas
Temps. - Nominal 1202 F - 1382 F, measured 100mm from the exhaust manifold flange."
Is that 100mm measured 1. "on the side of the pipe" 2. "on the outside curve
of the pipe" 3. "on the inside curve of the pipe" ? ...or does it matter?
Or should I just be consistent from pipe to pipe?
Thanks,
Mike
--------
Mike Miller @ millrml@aol.com
601 XL-B, 3300, Dynon
Remember, "the second mouse gets the cheese"!
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=306853#306853
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Installing EGT probes on 3300 |
Mike:
What that means is you measure DOWN from the flange - 100mm (3.936") drill a
hole an insert the probe. HOPEFULLY the EGT should read 1202 F (HA!) to
1382 F (HA!).
In reality what you want to do is have the probe located the SAME distance
down from the flange. Do NOT put the probe in a curve of the pipe. ALWAYS
TRY to keep all probes as close to the same setup as possible.
When reading the temps... DO NOT set in cement reading between other
planes. When you read your TEMPS you are LQQKing for what is normal for
your plane and CHANGES to that NORMAL.
The CLOSER to the flange the higher the temps.
The further away the lower the temps.
Probes on a bend ... WHO KNOWS!
If you read the installation instructions from the Gage Manufacture use
their recommendation.
YES - your reading may be different. BUT! As stated before... ALL reading
are ONLY a NORM for YOUR PLANE. YRMV
It is BETTER to go further down than too close.
But what is too close?
Why? Too close you will shorten the life of the probe. Higher Heat.
E.I. recommends 2.5" Down
JPI if I recall is the same.
I know, now you are really confused. AND don't Lose Your Head Below the
Window.
Sorry,
Barry
On Fri, Jul 30, 2010 at 5:34 PM, AZFlyer <millrML@aol.com> wrote:
>
> Page 24 of the Installation Manual for the 3300, last sentence says
> "Exhaust Gas Temps. - Nominal 1202 F - 1382 F, measured 100mm from the
> exhaust manifold flange."
>
> Is that 100mm measured 1. "on the side of the pipe" 2. "on the outside
> curve of the pipe" 3. "on the inside curve of the pipe" ? ...or does it
> matter?
>
> Or should I just be consistent from pipe to pipe?
>
> Thanks,
> Mike
>
> --------
> Mike Miller @ millrml@aol.com
> 601 XL-B, 3300, Dynon
>
> Remember, "the second mouse gets the cheese"!
>
>
> Read this topic online here:
>
> http://forums.matronics.com/viewtopic.php?p=306853#306853
>
>
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|