I talked to Dynon and studied the pressure problems with their other VDO senders.
My sender is for 0 to 50 psi and operating at around 2 to 3.5 psi. Should have
been 0 to 30 range.
Dynon is using a newer transducer with 3 wires but I don't want to go back thru
the firewall, remove the boot cowl on the Zodiac, run a new wire, disconnect
a plug and find another pin.
The very nice guy at Dynon support gave me the old VDO part number for the 0 to
30 psi sender. I found it at Summit racing before I found out that ACS also carries
it. VDO 360043D is the new number. I should have it in 4 or 5 days.
The old one has lasted more than 10 yrs so if I get half that on the new one I'll
be happy. I'll let ya'll know if it solves the problem.
Thanks again for the responses
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Fuel Pressure |
Good Going Bobby:
I would go with SUMMIT RACING before I buy anything from ACS!
Hey... Since re-stringing the wire through the old hole is a PITA, why not
just make a new hole.
Then - After you have proven the new setup cut the old wires out and plug
the old hole.
Barry
On Mon, Jan 29, 2018 at 8:33 PM, <BobbyPaulk@comcast.net> wrote:
> Thanks to Tim, Gary & Barry
> I talked to Dynon and studied the pressure problems with their other VDO
> senders.
> My sender is for 0 to 50 psi and operating at around 2 to 3.5 psi. Should
> have been 0 to 30 range.
> Dynon is using a newer transducer with 3 wires but I don't want to go back
> thru the firewall, remove the boot cowl on the Zodiac, run a new wire,
> disconnect a plug and find another pin.
> The very nice guy at Dynon support gave me the old VDO part number for the
> 0 to 30 psi sender. I found it at Summit racing before I found out that ACS
> also carries it. VDO 360043D is the new number. I should have it in 4 or 5
> days.
> The old one has lasted more than 10 yrs so if I get half that on the new
> one I'll be happy. I'll let ya'll know if it solves the problem.
>
> Thanks again for the responses
>
>
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|