Today's Message Index:
----------------------
1. 04:21 AM - Re: ventilation (Scott Stearns)
2. 05:30 AM - Re: ventilation ()
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
I put my OAT sensor in the aft portion of the wing root fairing. Seems to w
ork fine.
Scott
On Feb 26, 2012, at 2:36 PM, Galin Hernandez <galinhdz@gmail.com> wrote:
> Mine has no exhaust vent so I guess the opening works just fine.
>
> I have been debating about making a good seal on the rear bulkhead panel s
o I can use that area as a good place to put an outside air temperature sens
or, but now that you bring this up I may just leave it as it is.
>
> Galin
>
> On Sun, Feb 26, 2012 at 2:54 PM, ALFRED ROSA <fredorosa@gmail.com> wrote:
> I have a question to you people flying about cabin ventilation. I have 2 e
yeball vents on the panel for air intake
>
> but haven't provided any vent for exhausting cabin air. In an exhaust ven
t necessary or does the opening where
>
> the elevator passes through the rear fuselage act as an exhaust vent?
>
> Al
>
>
> et="_blank">http://www.matronics.com/Navigator?KIS-List
> tp://forums.matronics.com
> _blank">http://www.matronics.com/contribution
>
>
>
>
==========================
=========
==========================
=========
==========================
=========
==========================
=========
>
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
2/27/2012
Hello Al, My experience is that there is a significant flow of air (cold
in the winter) that arrives from the rear of the airplane into the
cockpit area when the eyeball vents are closed off.
Probably comes in around the opening in the fuselage tail where the
elevator spar goes through. I have not yet come up with a practical
means of blocking off this forward flowing cold air.
No problem with air flow coming into the cockpit through the eyeball
vents when they are open during the summer.
'OC' Baker Says: "The best investment we can make is the time and effort
to gather and understand knowledge.
=============
From: ALFRED ROSA
To: kisbuilders
Sent: Sunday, February 26, 2012 3:54 PM
Subject: KIS-List: ventilation
I have a question to you people flying about cabin ventilation. I
have 2 eyeball vents on the panel for air intake
but haven't provided any vent for exhausting cabin air. In an exhaust
vent necessary or does the opening where
the elevator passes through the rear fuselage act as an exhaust vent?
Al
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|