Today's Message Index:
----------------------
1. 06:50 AM - Re: 503 DCDI cutting out. (olendorf)
2. 07:20 AM - Re: Re: 503 DCDI cutting out. (Kirk Smith)
3. 08:14 AM - Re: Re: 503 DCDI cutting out. (Herb)
4. 12:14 PM - Re: 503 DCDI cutting out. (Kirkds)
5. 06:29 PM - Re: 503 DCDI cutting out. (John Hauck)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: 503 DCDI cutting out. |
Maybe something inside the electric pump is defective. You can remove the electric
pump entirely just for the test runs and see if that is causing the flow
restriction.
--------
Scott Olendorf
Original Firestar, Rotax 447, Powerfin prop
Schenectady, NY
http://sites.google.com/site/kolbfirestar/
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=443131#443131
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: 503 DCDI cutting out. |
I think the problem might be the pulse line. I used regular fuel tubing for
the pulse line and I was reminded it needs to be a heavier tubing than fuel
line. So maybe the pulse line is collapsing at high rpms? Anyway I ordered
some pulse line. Will know in a few days. Thx!
-----Original Message-----
From: olendorf
Sent: Saturday, June 6, 2015 9:49 AM
Subject: Kolb-List: Re: 503 DCDI cutting out.
Maybe something inside the electric pump is defective. You can remove the
electric pump entirely just for the test runs and see if that is causing the
flow restriction.
--------
Scott Olendorf
Original Firestar, Rotax 447, Powerfin prop
Schenectady, NY
http://sites.google.com/site/kolbfirestar/
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=443131#443131
-----
No virus found in this message.
Checked by AVG - www.avg.com
-----
No virus found in this message.
Checked by AVG - www.avg.com
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: 503 DCDI cutting out. |
Piece of fuel line from your local auto supply works fine..Matter of
fact,,,I use it entirely...Herb
On 06/06/2015 09:18 AM, Kirk Smith wrote:
>
> I think the problem might be the pulse line. I used regular fuel
> tubing for the pulse line and I was reminded it needs to be a heavier
> tubing than fuel line. So maybe the pulse line is collapsing at high
> rpms? Anyway I ordered some pulse line. Will know in a few days. Thx!
>
> -----Original Message----- From: olendorf
> Sent: Saturday, June 6, 2015 9:49 AM
> To: kolb-list@matronics.com
> Subject: Kolb-List: Re: 503 DCDI cutting out.
>
>
> Maybe something inside the electric pump is defective. You can remove
> the electric pump entirely just for the test runs and see if that is
> causing the flow restriction.
>
> --------
> Scott Olendorf
> Original Firestar, Rotax 447, Powerfin prop
> Schenectady, NY
> http://sites.google.com/site/kolbfirestar/
>
>
> Read this topic online here:
>
> http://forums.matronics.com/viewtopic.php?p=443131#443131
>
>
> -----
> No virus found in this message.
> Checked by AVG - www.avg.com
>
>
> -----
> No virus found in this message.
> Checked by AVG - www.avg.com
>
>
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: 503 DCDI cutting out. |
OK...I think I got it fixed. Found a video on Utube on cleaning the pump so I took
the old pump apart and cleaned it up . Then I took the replacement pump off
and put the old one back on. Tied the plane to the tractor and fired it up.
Ran it up to 5200rpms for 3 minutes back down and back up a few times. Ran perfectly
on the impulse pump. I'll take her up this evening for a flight check but
it looks like it's fixed. Thanks to everyone for the help.
--------
Kirk Smith
Columbiaville, MI
Firestar II
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=443142#443142
Message 5
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | 503 DCDI cutting out. |
Replace engine driven fuel pump.
john h
mkIII
Rock House, OR
-----Original Message-----
From: owner-kolb-list-server@matronics.com
[mailto:owner-kolb-list-server@matronics.com] On Behalf Of
Kirkds
Sent: Friday, June 05, 2015 8:58 AM
Subject: Kolb-List: 503 DCDI cutting out.
<kirk.smith@frontier.com>
I have a Firestar II with a Rotax 503 DCDI and it's been
cutting out. I replaced all the fuel lines, filter, and fuel
pump. When I turn on the electric pump the problem goes
away. Help!!!!
--------
Kirk Smith
Columbiaville, MI
Firestar II
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=443078#443078
=
Photoshare, and much much more:
=
=
=
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|