Thanks to Ross for the info....
Jerry's correct and the size they recommend for the flowmeter/transducer is -24
which ACS does not carry.
Anyone got a foot of -24 kicking around?
Either I was looking at the wrong page (likely) or ACS updated their website......
Ralph
-----Original Message-----
>From: Jerry Grimmonpre <jerry@mc.net>
>Sent: May 3, 2006 12:19 AM
>To: rv10-list@matronics.com
>Subject: Re: RV10-List: Re: RV-List: Firesleeving
>
>--> RV10-List message posted by: "Jerry Grimmonpre" <jerry@mc.net>
>
>AFP recommends firesleeve on the flow meter/transducer.
>Jerry Grimmonpre'
>RV8A Electrical
>
>----- Original Message -----
>From: "Ross Scroggs" <rv4ross@charter.net>
>To: <rv-list@matronics.com>; <rv6-list@matronics.com>;
><rv10-list@matronics.com>
>Sent: Tuesday, May 02, 2006 9:47 PM
>Subject: RV10-List: Re: RV-List: Firesleeving
>
>
>> --> RV10-List message posted by: "Ross Scroggs" <rv4ross@charter.net>
>>
>> Ralph,
>> According to the ACS catalog, page 122, the 303-4 hose uses AE102-9, the
>> 303-6 uses
>> AE102-12. Both firesleeve's use the 900591B-2C clamp.
>> Don't think I've ever seen firesleeve on a flow meter/transducer.
>>
>> Ross Scroggs
>> RV-4 #3911
>> Locust Grove, GA.
>>
>> ----- Original Message -----
>> From: "Ralph E. Capen" <recapen@earthlink.net>
>> To: <rv-list@matronics.com>; <rv6-list@matronics.com>;
>> <rv10-list@matronics.com>
>> Sent: Tuesday, May 02, 2006 9:38 AM
>> Subject: RV-List: Firesleeving
>>
>>
>>> --> RV-List message posted by: "Ralph E. Capen" <recapen@earthlink.net>
>>>
>>> Folks,
>>>
>>>>From what I've seen, most folks are not firesleeving their oil cooler
>>>>feed/return/pressure lines nor their fuel pressure line which I'm OK
>>>>with.
>>>
>>> Fuel feed/return lines I think need to be firesleeved.....
>>>
>>> I'm having a problem determining what size firesleeve to use. The ACS
>>> website has a table for their firesleeve parts which does not list the
>>> 303 hose that we're supposed to use.
>>>
>>> I'm getting ready to buy the stuff to build my fuel hoses - including the
>>> firesleeving. I'll be building an assembly that includes a pair of hoses
>>> and a fuel flow meter - I'm guessing that I'll need a larger chunk of
>>> firesleeve to go over the flow meter.
>>>
>>> Can anyone tell me what the correct size of Firesleeving is for a 303-4,
>>> 303-6, and Flowscan 201 fuel flow meter?
>>>
>>> Thanks,
>>> Ralph
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>
>>
>>
>>