    Time: 10:46:29 AM PST US
    Subject: regulators
    From: "dashwood" <dashwoodlock@hotmail.com>
    i have a 701 /912 with a ducati reg on it. got a low voltage warning last time out. checked resistance of two leads coming from engine coils shows 7.2 ohms. @ rotax manuel. the 12v dc side of the reg has a red wire out of firewall to first / next contact on reg. labeled alternator switch. the next contact is jump wired to first and 4th contact. 4th also has wire to 12000mfd capacitor and from there to solid ground. checked fuse panel and found a blown 15amp fuse on a wire labeled alternator. what was the builder trying to do with this fuse. i have been told by others if you shut off alternator loads while engine is running it will fry the reg. i have two switches on panel labeled master and alternator and was told always on shutdown one first then the other , never in the opposite order with threat of dire consequences. could this fuse be an over voltage / draw protection for the rest of the buss or has it somehow protected the reg from me fumbling with the panel switches. i have changed the fuse but not been able to test run engine and see if this fuse holds, due to howling blizzard here. hanger-ed but open into the wind today . -------- Ross Aalexander: CH701 driver 912ul 450tt Read this topic online here: http://forums.matronics.com/viewtopic.php?p=330780#330780


    Message 2


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 03:07:54 PM PST US
    Subject: Re: regulators
    From: Richard Girard <aslsa.rng@gmail.com>
    Ross, Suggest you review Section 17, pages 107-111 of the Rotax 912 Installation Manual. Rick Girard On Sat, Feb 12, 2011 at 12:43 PM, dashwood <dashwoodlock@hotmail.com> wrote: > dashwoodlock@hotmail.com> > > i have a 701 /912 with a ducati reg on it. got a low voltage warning last > time out. checked resistance of two leads coming from engine coils shows 7.2 > ohms. @ rotax manuel. the 12v dc side of the reg has a red wire out of > firewall to first / next contact on reg. labeled alternator switch. the next > contact is jump wired to first and 4th contact. 4th also has wire to > 12000mfd capacitor and from there to solid ground. checked fuse panel and > found a blown 15amp fuse on a wire labeled alternator. what was the builder > trying to do with this fuse. i have been told by others if you shut off > alternator loads while engine is running it will fry the reg. i have two > switches on panel labeled master and alternator and was told always on > shutdown one first then the other , never in the opposite order with threat > of dire consequences. could this fuse be an over voltage / draw protection > for the rest of the buss or has it somehow protected the reg from me > fumbling with the panel switches! > . i have changed the fuse but not been able to test run engine and see if > this fuse holds, due to howling blizzard here. hanger-ed but open into the > wind today . > > -------- > Ross Aalexander: CH701 driver 912ul 450tt > > > Read this topic online here: > > http://forums.matronics.com/viewtopic.php?p=330780#330780 > > -- Zulu Delta Mk IIIC Thanks, Homer GBYM It isn't necessary to have relatives in Kansas City in order to be unhappy. - Groucho Marx


    Message 3


  • INDEX
  • Back to Main INDEX
  • PREVIOUS
  • Skip to PREVIOUS Message
  • NEXT
  • Skip to NEXT Message
  • LIST
  • Reply to LIST Regarding this Message
  • SENDER
  • Reply to SENDER Regarding this Message
    Time: 06:15:23 PM PST US
    Subject: Re: regulators
    From: "dashwood" <dashwoodlock@hotmail.com>
    thanks. i was not able to find the pages i needed before. i think the fuse i have blown is the 25A after the reg terminals. the capacitor is in place and should have protected the reg as/per manual. when you close 16(master) then 19 relay pulls on the battery supply to fuse bus. i have an endurance fuse bus as well. somehow an alternator disconnect that draws minimal power only from battery to supply minimal flight requirements. i assume to guard against over voltage (failed reg). i don't see this in the diagram. not sure if master has to be shut off first to stop feedback( blowing the 25A fuse). i just want to understand what is happening so i can fix or not have happen in flight again. -------- Ross Aalexander: CH701 driver 912ul 450tt Read this topic online here: http://forums.matronics.com/viewtopic.php?p=330827#330827




    Other Matronics Email List Services

  • Post A New Message
  •   rotaxengines-list@matronics.com
  • UN/SUBSCRIBE
  •   http://www.matronics.com/subscription
  • List FAQ
  •   http://www.matronics.com/FAQ/RotaxEngines-List.htm
  • Web Forum Interface To Lists
  •   http://forums.matronics.com
  • Matronics List Wiki
  •   http://wiki.matronics.com
  • 7-Day List Browse
  •   http://www.matronics.com/browse/rotaxengines-list
  • Browse RotaxEngines-List Digests
  •   http://www.matronics.com/digest/rotaxengines-list
  • Browse Other Lists
  •   http://www.matronics.com/browse
  • Live Online Chat!
  •   http://www.matronics.com/chat
  • Archive Downloading
  •   http://www.matronics.com/archives
  • Photo Share
  •   http://www.matronics.com/photoshare
  • Other Email Lists
  •   http://www.matronics.com/emaillists
  • Contributions
  •   http://www.matronics.com/contribution

    These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.

    -- Please support this service by making your Contribution today! --