Folks,
>From what I've seen, most folks are not firesleeving their oil cooler feed/return/pressure
lines nor their fuel pressure line which I'm OK with.
Fuel feed/return lines I think need to be firesleeved.....
I'm having a problem determining what size firesleeve to use. The ACS website
has a table for their firesleeve parts which does not list the 303 hose that we're
supposed to use.
I'm getting ready to buy the stuff to build my fuel hoses - including the firesleeving.
I'll be building an assembly that includes a pair of hoses and a fuel
flow meter - I'm guessing that I'll need a larger chunk of firesleeve to go
over the flow meter.
Can anyone tell me what the correct size of Firesleeving is for a 303-4, 303-6,
and Flowscan 201 fuel flow meter?
Thanks,
Ralph
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: RV-List: Firesleeving |
--> RV6-List message posted by: "Ross Scroggs" <rv4ross@charter.net>
Ralph,
According to the ACS catalog, page 122, the 303-4 hose uses AE102-9, the
303-6 uses
AE102-12. Both firesleeve's use the 900591B-2C clamp.
Don't think I've ever seen firesleeve on a flow meter/transducer.
Ross Scroggs
RV-4 #3911
Locust Grove, GA.
----- Original Message -----
From: "Ralph E. Capen" <recapen@earthlink.net>
<rv10-list@matronics.com>
Sent: Tuesday, May 02, 2006 9:38 AM
Subject: RV-List: Firesleeving
> --> RV-List message posted by: "Ralph E. Capen" <recapen@earthlink.net>
>
> Folks,
>
>>From what I've seen, most folks are not firesleeving their oil cooler
>>feed/return/pressure lines nor their fuel pressure line which I'm OK with.
>
> Fuel feed/return lines I think need to be firesleeved.....
>
> I'm having a problem determining what size firesleeve to use. The ACS
> website has a table for their firesleeve parts which does not list the 303
> hose that we're supposed to use.
>
> I'm getting ready to buy the stuff to build my fuel hoses - including the
> firesleeving. I'll be building an assembly that includes a pair of hoses
> and a fuel flow meter - I'm guessing that I'll need a larger chunk of
> firesleeve to go over the flow meter.
>
> Can anyone tell me what the correct size of Firesleeving is for a 303-4,
> 303-6, and Flowscan 201 fuel flow meter?
>
> Thanks,
> Ralph
>
>
>