      Thanks to Ross for the info....
      
      Jerry's correct and the size they recommend for the flowmeter/transducer is -24
      which ACS does not carry.
      
      Anyone got a foot of -24 kicking around?
      
      Either I was looking at the wrong page (likely) or ACS updated their website......
      
      Ralph
      
      -----Original Message-----
      >From: Jerry Grimmonpre <jerry@mc.net>
      >Sent: May 3, 2006 12:19 AM
      >To: rv10-list@matronics.com
      >Subject: Re: RV10-List: Re: RV-List: Firesleeving
      >
      >--> RV10-List message posted by: "Jerry Grimmonpre" <jerry@mc.net>
      >
      >AFP recommends firesleeve on the flow meter/transducer.
      >Jerry Grimmonpre'
      >RV8A Electrical
      >
      >----- Original Message ----- 
      >From: "Ross Scroggs" <rv4ross@charter.net>
      >To: <rv-list@matronics.com>; <rv6-list@matronics.com>; 
      ><rv10-list@matronics.com>
      >Sent: Tuesday, May 02, 2006 9:47 PM
      >Subject: RV10-List: Re: RV-List: Firesleeving
      >
      >
      >> --> RV10-List message posted by: "Ross Scroggs" <rv4ross@charter.net>
      >>
      >> Ralph,
      >>   According to the ACS catalog, page 122, the 303-4 hose uses AE102-9, the 
      >> 303-6 uses
      >> AE102-12.  Both firesleeve's use the 900591B-2C clamp.
      >>  Don't think I've ever seen firesleeve on a flow meter/transducer.
      >>
      >> Ross Scroggs
      >> RV-4 #3911
      >> Locust Grove, GA.
      >>
      >> ----- Original Message ----- 
      >> From: "Ralph E. Capen" <recapen@earthlink.net>
      >> To: <rv-list@matronics.com>; <rv6-list@matronics.com>; 
      >> <rv10-list@matronics.com>
      >> Sent: Tuesday, May 02, 2006 9:38 AM
      >> Subject: RV-List: Firesleeving
      >>
      >>
      >>> --> RV-List message posted by: "Ralph E. Capen" <recapen@earthlink.net>
      >>>
      >>> Folks,
      >>>
      >>>>From what I've seen, most folks are not firesleeving their oil cooler 
      >>>>feed/return/pressure lines nor their fuel pressure line which I'm OK 
      >>>>with.
      >>>
      >>> Fuel feed/return lines I think need to be firesleeved.....
      >>>
      >>> I'm having a problem determining what size firesleeve to use.  The ACS 
      >>> website has a table for their firesleeve parts which does not list the 
      >>> 303 hose that we're supposed to use.
      >>>
      >>> I'm getting ready to buy the stuff to build my fuel hoses - including the 
      >>> firesleeving.  I'll be building an assembly that includes a pair of hoses 
      >>> and a fuel flow meter - I'm guessing that I'll need a larger chunk of 
      >>> firesleeve to go over the flow meter.
      >>>
      >>> Can anyone tell me what the correct size of Firesleeving is for a 303-4, 
      >>> 303-6, and Flowscan 201 fuel flow meter?
      >>>
      >>> Thanks,
      >>> Ralph
      >>>
      >>>
      >>>
      >>>
      >>>
      >>>
      >>>
      >>>
      >>>
      >>>
      >>>
      >>>
      >>>
      >>>
      >>
      >>
      >>
      >>