--> RV9-List message posted by: JVonDolen@aol.com
Steve, I don't know if you have been able to seal your filler caps yet or not
or what else has transpired since you posted, but here are my comments:
First of all, 2" drop every 30 minutes from only a 10" differential is not a
minute leak, it is one that can be easily seen with a soap solution (I
brushed mine on rather than sprayed). I was getting leaks from my filler caps too
but was able to seal them (for test purposes) with duct tape but I had to work
at it, ie, clean the surface around the cap with a solvent then apply liberal
duct tape very carefully.
After getting the caps sealed I was still getting a slow drop in my water
manometer from a starting point of about 25", and all the areas around the end
plate were not leaking. So even tho I have QB wings/tanks I decided to check all
the rivets and seams. On one tank I found two leaking baffle rivets, one in
the top and one on the bottom. They would "bubble" quite noticeably, and after
sealing with my beloved duct tape no more bubbles and the manometer held its
level for several days (varying of course with temperature and baro pressure).
The factory suggested using Loctite or Permatex thread locker, penetrating
grade (green color). The fluid wicks into the leak and seals it, they said. I
did this and sure enough, no leaks, either top or bottom. But I'm still a little
worried about how permanent this solution is.
Harold Kovac, I sure would be interested to hear more about how you drilled
those 5 rivets out. Were they hard to remove since they were imbeded in cured
Proseal, and
did you have any concerns about getting debris (sp) inside your tank? Were
they pop rivets or solid ones?
John Von Dohlen
Canopy
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: More on Tank Leaks |
--> RV9-List message posted by: "Harold Kovac" <kayce@sysmatrix.net>
Hi John,
I had 5 rivets in a row on one side of the baffle flange area, just drilled
them out , cleaned up the dimples/holes with MEK, mixed a bit of Pro Seal,
then
re-riveted, next day checked with the manometer and NO LEAK. I lost about
4-5 weeks trying suds , gooping up all the flange rivets on the baffle , and
end sides, and no joy...when the neighor pulled the winter cover from his
pool I did a dunk and solved my problem ....finally. Good luck
Harold 9A working on completing wings
----- Original Message -----
From: <JVonDolen@aol.com>
Subject: RV9-List: More on Tank Leaks
> --> RV9-List message posted by: JVonDolen@aol.com
>
> Steve, I don't know if you have been able to seal your filler caps yet or
not
> or what else has transpired since you posted, but here are my comments:
>
> First of all, 2" drop every 30 minutes from only a 10" differential is
not a
> minute leak, it is one that can be easily seen with a soap solution (I
> brushed mine on rather than sprayed). I was getting leaks from my filler
caps too
> but was able to seal them (for test purposes) with duct tape but I had to
work
> at it, ie, clean the surface around the cap with a solvent then apply
liberal
> duct tape very carefully.
>
> After getting the caps sealed I was still getting a slow drop in my water
> manometer from a starting point of about 25", and all the areas around the
end
> plate were not leaking. So even tho I have QB wings/tanks I decided to
check all
> the rivets and seams. On one tank I found two leaking baffle rivets, one
in
> the top and one on the bottom. They would "bubble" quite noticeably, and
after
> sealing with my beloved duct tape no more bubbles and the manometer held
its
> level for several days (varying of course with temperature and baro
pressure).
>
> The factory suggested using Loctite or Permatex thread locker, penetrating
> grade (green color). The fluid wicks into the leak and seals it, they
said. I
> did this and sure enough, no leaks, either top or bottom. But I'm still a
little
> worried about how permanent this solution is.
>
> Harold Kovac, I sure would be interested to hear more about how you
drilled
> those 5 rivets out. Were they hard to remove since they were imbeded in
cured
> Proseal, and
> did you have any concerns about getting debris (sp) inside your tank? Were
> they pop rivets or solid ones?
>
> John Von Dohlen
> Canopy
>
>
Other Matronics Email List Services