Today's Message Index:
----------------------
1. 04:50 PM - Re: Running on both ign's & more (Larry McFarland)
2. 05:02 PM - Re: Running on both ign's & more (Hinde, Frank George (Corvallis))
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Running on both ign's & more |
--> Stratus-List message posted by: "Larry McFarland" <larrymc@qconline.com>
Does placing the TP45 on a heat sink near a coil on the firewall
put it in any difficulty with moisture thru the cowl? I wrapped the .040
perforated heat sink with half an inch of clearance around the module
and they are directly behind the left carb elbow with an inch of clearance.
That is, could one of these be expected to fail to operate in the rain?
Larry
Its just the ignitor chip that dies.
>
> As to the Stratus 2nd ignition, well that seems to fail at a remarkably
> high rate too I've known of about 4 of them incuding mine. I didn't even
> bother getting a price just dumped it all and built the twin TP45
> system. I'm very happy...At least as long as the dizzy shaft wear does
> not become excessive.
> Frank
>
> 601 Stratus with Ram heads 340 hours
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Running on both ign's & more |
--> Stratus-List message posted by: "Hinde, Frank George (Corvallis)" <frank.hinde@hp.com>
Shouldn't be a problem. The TP45's are only switching low voltage so as
long as the connections are good they will work fine.
The high tension side of the coils are much more likely to fail in the
rain but mine have run just fine in such conditions.
Frank
-----Original Message-----
From: owner-stratus-list-server@matronics.com
[mailto:owner-stratus-list-server@matronics.com] On Behalf Of Larry
McFarland
Subject: Re: Stratus-List: Running on both ign's & more
--> Stratus-List message posted by: "Larry McFarland"
--> <larrymc@qconline.com>
Does placing the TP45 on a heat sink near a coil on the firewall put it
in any difficulty with moisture thru the cowl? I wrapped the .040
perforated heat sink with half an inch of clearance around the module
and they are directly behind the left carb elbow with an inch of
clearance. That is, could one of these be expected to fail to operate in
the rain?
Larry
Its just the ignitor chip that dies.
>
> As to the Stratus 2nd ignition, well that seems to fail at a
> remarkably high rate too I've known of about 4 of them incuding mine.
> I didn't even bother getting a price just dumped it all and built the
> twin TP45 system. I'm very happy...At least as long as the dizzy shaft
> wear does not become excessive.
> Frank
>
> 601 Stratus with Ram heads 340 hours
==
direct advertising on the Matronics Forums.
==
==
==
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|