Today's Message Index:
----------------------
1. 09:44 AM - Re: XDP-210EQ Relay on Remote problem... (Colin (DP Motorsport))
2. 03:23 PM - SQXPERT (Pete)
3. 03:29 PM - Re: SQXPERT (NOTGSXR@aol.com)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | XDP-210EQ Relay on Remote problem... |
--> XDP4000X-List message posted by: "Colin (DP Motorsport)" <colin@dp-motorsport.co.uk>
I'd imagine from what your saying there is something wrong with the
relay.
Does the light come on in the 210 when there is no live connceted to the
relay?
-----Original Message-----
From: owner-xdp4000x-list-server@matronics.com
[mailto:owner-xdp4000x-list-server@matronics.com] On Behalf Of Roland M
Subject: XDP4000X-List: XDP-210EQ Relay on Remote problem...
--> XDP4000X-List message posted by: "Roland M" <mdx400@hotmail.com>
Recently I was doing some rewiring in my car, replacing my old alarm
with a
new one and doing a few other things since the weather is nice now :)
Anyway I was always running my remote from my head unit using a relay on
the
remote wire since I'm running two amplifiers and an active electronic
crossover (for bi-amping my components) and I thought using the relay is
just cheap insurance plus it allows me to add other amps without any
worry.
Well I decided to do away with the wire going from the HU to the back
and
simply run the remote from the XDP unit's remote terminal. Again I
decided
that a relay would be a good idea on the remote line, just-in-case.
But I
had something very strange occur when I tried to use the relay on the
XDP's
remote terminal.
Connecting one side of the coil to ground and the other side to the
remote
terminal would instantly cause the green POWER indicator light on the
XDP to
come on, and stay on, at about half its normal brightness. It's as if
it
were giving me a "signal" that I wired something incorrectly. Removing
the
relay and simply connecting the remote wire directly did not cause this.
I find this to be very strange behaviour since I don't think there is
any
reason to be doing this. I even tried using a diode across the coil of
the
relay as is sometimes required but it still did the same thing, the
light on
the XDP comes on.
Has anyone else encountered this on either a 210EQ or a 4000X or know
what's
going on (or what I'm doing wrong)? It seems to be holding up without
the
relay as of right now but with a 300mA limit on the remote output on the
XDP
I'm guessing if I add anything else I'm going to have to go off the HU's
remote line, to be safe?
For reference, all I'm doing is connecting a regular SPDT relay with one
side of the coil (85) to the remote terminal on the XDP, the other side
(86)
to ground, the output pin (30) to the amps&xover, and finally pin (87)
to
+12V. It doesn't matter if I wire the whole thing up or not; as soon as
+I
connect one side of the coil to ground and the other side to the remote
terminal the power light turns on...
Roland M.
Watch the online reality show Mixed Messages with a friend and enter to
win
a trip to NY
http://www.msnmessenger-download.click-url.com/go/onm00200497ave/direct/
01/
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
--> XDP4000X-List message posted by: Pete <dabrow@orange.net>
Hi all,
I have been trying to contact sqxpert on the list because I bought an
xdp-4000x from him. It was advertised on this list ages back.
Does anyone know him or have any contact details as I can't get hold of
him at the moment (believe me, I have tried).
Thanks guys,
Pete
---
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
--> XDP4000X-List message posted by: NOTGSXR@aol.com
In a message dated 6/22/04 6:23:47 PM Eastern Daylight Time,
dabrow@orange.net writes:
Hi all,
I have been trying to contact sqxpert on the list because I bought an
xdp-4000x from him. It was advertised on this list ages back.
Does anyone know him or have any contact details as I can't get hold of
him at the moment (believe me, I have tried).
Thanks guys,
Pete
Pete, his email is _Sqxpert@aol.com_ (mailto:Sqxpert@aol.com) ..... I
talked with him about buying his unit to swap out the front plate of mine....
but
you beat me to it......... lol.. Oh well........ anyone know Tim???????
Hopefully we don't have to send out the Lynch Mob!!!!