Subject: | Re: Electric boost pump CJ6 |
Typo error in original message. Should be 32 GPH instead of GPM.
Paul
On Sun, Oct 23, 2011 at 8:57 PM, <cjpilot710@aol.com> wrote:
> **
> Make sure you have in / out lines hooked up properly.
> Pappy
>
> In a message dated 10/23/2011 11:30:01 P.M. Eastern Daylight Time,
> vplewis@community.org writes:
>
>
> Guys, I have installed an electric fuel boost pump to replace the wobble
> pump in my CJ6. It is a 3-5 psi, 32 gpm flow thru pump that will allow fuel
> to pass even if it is not running. I removed the wobble pump & the lines to
> the check valve & mounted the pump inside the belly with lines to the check
> valve the same as the wobble pump lines. I have fuel flowing on the
> pressure side of the pump, but there is no fuel flowing into the fuel pump
> on the engine. I think the pump is just forcing the fuel thru the small by
> pass lines on the check valve & back into the pump. I am planning to plug
> the small by pass lines, so that the fuel will be pumped up to the engine.
> Any thoughts or suggestions? Thanks.
>
> Paul Lewis
>
>
> Read this topic online here:
>
> http://forums.matronics.com/viewtopic.php?p=355839#355839**
>
>
> *
>
> *
>
>
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Electric boost pump CJ6 |
Paul
If it is a vane type pump you must ensure that the relief & by-pass
assembly is correctly mounted in relation to the direction of rotation.
Unless the ENGINE driven pump is an internal by-pass type the new
auxiliary pump will NOT deliver fuel through a static engine pump.
It SHOULD be a py-pass type pump since the emergency fuel from the
wobble pump is delivered in series. If non bypass it would have to be a
parallel system.
The by-pass around the check valve is necessary I would not recommend
plugging it.
Walt
----- Original Message -----
From: Paul Lewis
To: yak-list@matronics.com
Sent: Monday, October 24, 2011 8:38 AM
Subject: Re: Yak-List: Electric boost pump CJ6
Typo error in original message. Should be 32 GPH instead of GPM.
Paul
On Sun, Oct 23, 2011 at 8:57 PM, <cjpilot710@aol.com> wrote:
Make sure you have in / out lines hooked up properly.
Pappy
In a message dated 10/23/2011 11:30:01 P.M. Eastern Daylight Time,
vplewis@community.org writes:
<vplewis@community.org>
Guys, I have installed an electric fuel boost pump to replace the
wobble pump in my CJ6. It is a 3-5 psi, 32 gpm flow thru pump that will
allow fuel to pass even if it is not running. I removed the wobble pump
& the lines to the check valve & mounted the pump inside the belly with
lines to the check valve the same as the wobble pump lines. I have fuel
flowing on the pressure side of the pump, but there is no fuel flowing
into the fuel pump on the engine. I think the pump is just forcing the
fuel thru the small by pass lines on the check valve & back into the
pump. I am planning to plug the small by pass lines, so that the fuel
will be pumped up to the engine. Any thoughts or suggestions? Thanks.
Paul Lewis
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=355839#355839
et="_blank">http://www.matronics.com/Navigator?Yak-List
tp://forums.matronics.com
_blank">http://www.matronics.com/contribution
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Electric boost pump CJ6 |
Walt, I disconnected the fuel hose to the engine pump & there is no fuel
reaching that point when I turn on the boost pump. The fuel line from the
boost pump to the engine side of the check valve is pumping fuel, but how
can it pump up to the engine with the by pass line installed. What is the
purpose of the by pass line even with the standard wobble pump?
On , Walter Lannon <wlannon@shaw.ca> wrote:
> Paul
> If it is a vane type pump you must ensure that the
> relief & by-pass assembly is correctly mounted in relation to the
> direction
> of rotation.
> Unless the ENGINE driven pump is an internal
> by-pass type the new auxiliary pump will NOT deliver fuel through a static
> engine pump.
> It SHOULD be a py-pass type pump since the
> emergency fuel from the wobble pump is delivered in series. If non
> bypass it would have to be a parallel system.
> The by-pass around the check valve is necessary I
> would not recommend plugging it.
> Walt
> ----- Original Message -----
> From:
> Paul
> Lewis
> To: yak-list@matronics.com
> Sent: Monday, October 24, 2011 8:38
> AM
> Subject: Re: Yak-List: Electric boost
> pump CJ6
> Typo error in original message. Should be 32 GPH instead of
> GPM.
> Paul
> On Sun, Oct 23, 2011 at 8:57 PM, cjpilot710@aol.com> wrote:
> Make sure you have in / out lines hooked up properly.
> Pappy
> In a message dated 10/23/2011 11:30:01 PM Eastern Daylight Time,
> vplewis@community.org
> writes:
> Guys, I have installed
> an electric fuel boost pump to replace the wobble pump in my CJ6. It
> is a 3-5 psi, 32 gpm flow thru pump that will allow fuel to pass even if
> it is not running. I removed the wobble pump & the lines to the
> check valve & mounted the pump inside the belly with lines to the
> check valve the same as the wobble pump lines. I have fuel flowing
> on the pressure side of the pump, but there is no fuel flowing into the
> fuel pump on the engine. I think the pump is just forcing the fuel
> thru the small by pass lines on the check valve & back into the
> pump. I am planning to plug the small by pass lines, so that the
> fuel will be pumped up to the engine. Any thoughts or
> suggestions? Thanks.
> Paul Lewis
> Read this
> topic online here:
> http://forums.matronics.com/viewtopic.php?p=355839#355839
> et="_blank">http://www.matronics.com/Navigator?Yak-List
> tp://forums.matronics.com
> _blank">http://www.matronics.com/contribution
> href="http://www.matronics.com/Navigator?Yak-List">http://www.matronics.com/Navigator?Yak-List
> href="http://forums.matronics.com">http://forums.matronics.com
> href="http://www.matronics.com/contribution">http://www.matronics.com/c
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|