Today's Message Index:
----------------------
1. 01:59 PM - Re: Fuel Tanks (Yak Driver)
2. 07:05 PM - Re: Re: Fuel Tanks (Roger Kemp M.D.)
3. 07:22 PM - Re: Re: Fuel Tanks (Richard Goode)
4. 07:31 PM - Yak-50 ignition troubleshooting (moose8154)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Richard,
What stops the fuel from the aux tank flowing down and into the existing main tanks?
YD
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=381181#381181
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
In the 52, flapper valves. In the 78 50, nothing. It is a direct gravity feed without
a back flow flapper valve. In the later 50's, it is manually done with
a transfer pump.
Doc
Sent from my iPad
On Aug 18, 2012, at 3:57 PM, "Yak Driver" <antdea2000@yahoo.com.au> wrote:
>
> Richard,
>
> What stops the fuel from the aux tank flowing down and into the existing main
tanks?
>
> YD
>
>
>
>
> Read this topic online here:
>
> http://forums.matronics.com/viewtopic.php?p=381181#381181
>
>
>
>
>
>
>
>
>
>
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
The standard non-return valves which normally stop the fuel cross-feeding
from one wing to the other.
Richard
Rhodds Farm
Lyonshall
Hereford
HR5 3LW
United Kingdom
-----Original Message-----
From: owner-yak-list-server@matronics.com
[mailto:owner-yak-list-server@matronics.com] On Behalf Of Yak Driver
Sent: Sunday, August 19, 2012 2:27 AM
Subject: Yak-List: Re: Fuel Tanks
Richard,
What stops the fuel from the aux tank flowing down and into the existing
main tanks?
YD
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=381181#381181
--
This message has been scanned for viruses and dangerous content by
MailScanner, and is believed to be clean.
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Yak-50 ignition troubleshooting |
Hi,
My shower of sparks stopped working... Can someone give me some tips on how to
proceed to troubleshoot this issue?
Thanks,
Olivier
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=381204#381204
Other Matronics Email List Services
These Email List Services are sponsored solely by Matronics and through the generous Contributions of its members.
-- Please support this service by making your Contribution today! --
|