Today's Message Index:
----------------------
1. 08:08 PM - Re: CJ Nose gear won't retract (Walter Lannon)
Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: CJ Nose gear won't retract |
Gil;
Agree, not the usual suspect this time. All I can think of right now :--
1. Failed internal actuator seal, air going to both sides. 2. Similar
internal failure of the diverter valve with same result. 3. Mechanical
failure of the ball-lock assy. in the actuator, preventing it's release.
Unlikely unless very high TSO and/or improper adjustment of drag link
over-centre down-lock.
All just guesswork.
Walt
-----Original Message-----
From: glipaz
Sent: Saturday, October 14, 2017 5:59 PM
Subject: Yak-List: CJ Nose gear won't retract
I flew three hops today and on the last one the nose gear would not retract
after takeoff. It remained down and locked with a green light. Mains
worked fine and showed Red lights for up and locked. Recycled a couple
times but it didn't help. I know there's a check valve on the firewall but
if it was leaking into the Emerg down air, I believe the mains would also
have remained down.
Any help is appreciated.
Gil
Read this topic online here:
http://forums.matronics.com/viewtopic.php?p=473560#473560
---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus