Message 1
INDEX | Back to Main INDEX |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Firewall pass through |
I am changing my batteries from in front of the firewall to behind the seat.
The existing firewall pass through bolts are 1/4" . Will this still be
sufficient for bringing power from inside back to the engine compartment?
Jim
James Robinson
Glasair lll N79R
Spanish Fork UT U77
________________________________
From: "Robert L. Nuckolls, III" <nuckolls.bob@aeroelectric.com>
Sent: Wed, May 4, 2011 4:58:21 PM
Subject: Re: AeroElectric-List: Harbor Freight Hydraulic Crimper
<nuckolls.bob@aeroelectric.com>
At 05:31 PM 5/4/2011, you wrote:
> HFT sent me a 20% off coupon with no limit on sale items so I treated myself
to
>one of their Hydraulic Crimping Tools (part no 66150) for $39.95. When I got it
>home I was surprised at how small the crimping dies were. I'm not sure they're
>sized for the wire, much less the connector.
> The picture shows the AWG 4 dies with an Amp # 4 connector.
> Does anyone have experience using this tool? I'd like to hear from you before
I
>make up my mind whether to keep the tool or not.
Go ahead and put a terminal onto a 4AWG wire
and see what it looks like. I might have you send
me the installed terminal and I'll slice it open
for microscopic examination. How many die sets
come with the tool?
Bob . . .
Message 2
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Firewall pass through |
Jim,
Are the =BC bolts built into a firewall device designed specifically for pa
ssing cables through? If so, does it have a rating? I've seen similar in th
e racing world where they bolt the connection through. These work perfectly
fine so long as you have the correct device intended for the job.
The below uses a 3/8 bolt, but there are many variations on this product. I
f you go this route be sure to protect the exposed bolt from contact with o
ther gremlins. Some come with covers.
http://www.google.com/products/catalog?hl=en&biw=1403&bih=738&q=fir
ewall+battery+terminals&um=1&ie=UTF-8&cid=15926373037678662275&sa=X
&ei=YrXCTYqEI-rj0QGkkqXtAw&ved=0CEMQ8wIwAw#
Glenn E. Long
From: owner-aeroelectric-list-server@matronics.com [mailto:owner-aeroelectr
ic-list-server@matronics.com] On Behalf Of James Robinson
Sent: Thursday, May 05, 2011 10:10 AM
Subject: AeroElectric-List: Re: Firewall pass through
I am changing my batteries from in front of the firewall to behind the seat
. The existing firewall pass through bolts are 1/4" . Will this still be
sufficient for bringing power from inside back to the engine compartment?
Jim
James Robinson
Glasair lll N79R
Spanish Fork UT U77
Message 3
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: EL lighting-wire causing noise |
Thanks Ken,
I've a couple in the electronics box from when I made some dimmed map
lights. I'll give that a try.
James
On 5 May 2011 01:35, Ken <klehman@albedo.net> wrote:
>
> FWIW my EL lights are powered through the homemade analog dimmer circuit on
> the aeroelectric pages and there is no noise evident at any brightness. I
> think the circuit used a LM317 regulator.
> Ken
>
> On 5/2/2011 8:43 AM, Tim Olson wrote:
>>
>>
>> That's exactly what I did when I had the same issue. Those EL lights
>> aren't the quietest things. The LED's are quiet though.
>>
>> Tim Olson - RV-10 N104CD
>> do not archive
>>
>>
>> On 5/2/2011 7:25 AM, Eric M. Jones wrote:
>>>
>>> Jones"<emjones@charter.net>
>>>
>>> My philosophy is that changing to an LED strip is the easy way to go.
>>> You can fix the EL problems, but does it make sense?
>>>
>>> --------
>>> Eric M. Jones
>>> www.PerihelionDesign.com
>>> 113 Brentwood Drive
>>> Southbridge, MA 01550
>>> (508) 764-2072
>>> emjones@charter.net
>>>
>>>
>
>
Message 4
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Firewall pass through |
>
>http://www.google.com/products/catalog?hl=en&biw=1403&bih=738&q=firewall+battery+terminals&um=1&ie=UTF-8&cid=15926373037678662275&sa=X&ei=YrXCTYqEI-rj0QGkkqXtAw&ved=0CEMQ8wIwAw#
Emacs!
Fire wall feed-thru products like this are electrically
adequate and VERY convenient. Just be aware that plastic
insulators would not pass muster in the TC aircraft
world with respect to maintaining fire wall integrity.
Admittedly, fuel fed fires under the cowl are VERY
rare events . . . and we know that those-who-know-more-
about-airplanes-than-we-do are fond of writing rules
for mitigating the rarest of risks.
A lighter, less elegant but time honored and much tested
approach is to bring unbroken wires through the fire wall
protected by shielded grommets and sealed with a fillet
of fire-putty on the engine side.
It's your airplane . . . your call.
Bob . . .
Message 5
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Harbor Freight Hydraulic Crimper |
At 09:07 PM 5/4/2011, you wrote:
>12, 10, 8, 7, 6, 4, 2, 0, 00
>
>Rick
Yeah, went to the website and looked it up.
That's a pretty good range. Too bad they
didn't make those hex shaped holes tailored
more closely to the real-world of terminals.
But then, we have no knowledge of what the
designers were handed for design goals . . .
nor the market demands that drove the decision
to fabricate the tool.
I'll be interested in seeing what your test
crimps look like.
Bob . . .
Message 6
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Harbor Freight Hydraulic Crimper |
FYI
T&B has a rental program for tools like this. Might be a better choice than
using a universal crimper.
http://www.tnb.com/ps/con/contractor.cgi?action=tool&ca=corp
Regards
Ron Raby
----- Original Message -----
From: "Robert L. Nuckolls, III" <nuckolls.bob@aeroelectric.com>
Sent: Thursday, May 05, 2011 10:06 AM
Subject: Re: AeroElectric-List: Harbor Freight Hydraulic Crimper
> <nuckolls.bob@aeroelectric.com>
>
> At 09:07 PM 5/4/2011, you wrote:
>>12, 10, 8, 7, 6, 4, 2, 0, 00
>>
>>Rick
>
> Yeah, went to the website and looked it up.
> That's a pretty good range. Too bad they
> didn't make those hex shaped holes tailored
> more closely to the real-world of terminals.
>
> But then, we have no knowledge of what the
> designers were handed for design goals . . .
> nor the market demands that drove the decision
> to fabricate the tool.
>
> I'll be interested in seeing what your test
> crimps look like.
>
>
> Bob . . .
>
>
>
Message 7
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: EL lighting-wire causing noise |
If it is quiet I can look up the resistor values that I used to adjust
the voltages to something more suitable. I think full dim for my EL
inverter cube was around 5 or 6 volts so I altered the design a bit to
still have full range adjustment on the knob.
Ken
On 5/5/2011 10:50 AM, James Kilford wrote:
> --> AeroElectric-List message posted by: James Kilford<james@etravel.org>
>
> Thanks Ken,
>
> I've a couple in the electronics box from when I made some dimmed map
> lights. I'll give that a try.
>
> James
>
> On 5 May 2011 01:35, Ken<klehman@albedo.net> wrote:
>> --> AeroElectric-List message posted by: Ken<klehman@albedo.net>
>>
>> FWIW my EL lights are powered through the homemade analog dimmer circuit on
>> the aeroelectric pages and there is no noise evident at any brightness. I
>> think the circuit used a LM317 regulator.
>> Ken
>>
Message 8
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | Re: Firewall pass through |
Concerning firewall pass-through trinkets...I found a company called Precis
ion =0AGrommets and they will custom make these in a variety of materials a
nd sizes. =0AHere is a blip on how I put them in my Kitfox=C2- =0Ahttp://
www.azshowersolutions.com/Engine13.html=0AI was very happy with their servi
ce and product.=0ADan=0A=0A=0A>=0A>From: "longg@pjm.com" <longg@pjm.com>=0A
>To: aeroelectric-list@matronics.com=0A>Sent: Thu, May 5, 2011 7:37:12 AM
=0A>Subject: RE: AeroElectric-List: Re: Firewall pass through=0A>=0A>=0A>Ji
m,=0A>=C2-=0A>Are the =C2=BC bolts built into a firewall device designed
specifically for passing =0A>cables through? If so, does it have a rating?
I=99ve seen similar in the racing =0A>world where they bolt the conne
ction through. These work perfectly fine so long =0A>as you have the correc
t device intended for the job.=0A>=C2-=0A>The below uses a 3/8 bolt, but
there are many variations on this product. If you =0A>go this route be sure
to protect the exposed bolt from contact with other =0A>gremlins. Some com
e with covers.=0A>=C2-=0A>http://www.google.com/products/catalog?hl=en&
biw=1403&bih=738&q=firewall+battery+terminals&um=1&ie=UTF-8&cid
=15926373037678662275&sa=X&ei=YrXCTYqEI-rj0QGkkqXtAw&ved=0CEMQ8wIwA
w#=0A>=0A>=C2-=0A>Glenn E. Long=0A>=C2-=0A>From:owner-aeroelectric-list
-server@matronics.com =0A>[mailto:owner-aeroelectric-list-server@matronics.
com] On Behalf Of James =0A>Robinson=0A>Sent: Thursday, May 05, 2011 10:10
AM=0A>To: aeroelectric-list@matronics.com=0A>Subject: AeroElectric-List: Re
: Firewall pass through=0A>=C2-=0A>I am changing my batteries from in fro
nt of the firewall to behind the seat.=C2- =0A>The existing firewall pass
through bolts are 1/4" .=C2- Will this still be =0A>sufficient for bring
ing power from inside back to the engine compartment?=0A>Jim=0A>=C2-=0A>J
ames Robinson=0A>Glasair lll N79R=0A>Spanish Fork UT U77=0A>=C2-=0A> =C2
======================= =0A>
Message 9
INDEX | Back to Main INDEX |
PREVIOUS | Skip to PREVIOUS Message |
NEXT | Skip to NEXT Message |
LIST | Reply to LIST Regarding this Message |
SENDER | Reply to SENDER Regarding this Message |
|
Subject: | There was a time when 488,000 pound airplanes were |
pretty amazing. . .
I think I used to hear numbers for gross weight on the B-52H
models as topping out near 500K pounds. Here's a rejected take
off test on the 747-8 loaded to nearly a million pounds. This
is what you call "really hot stuff" . . . no pun intended.
http://tinyurl.com/42lrcss
Bob . . .